Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Quantitative risk assessment (QRA) for skin sensitization is used to derive safe use levels of sensitising fragrance ingredients in products. Post-marketing surveillance of the prevalence of contact allergy to these ingredients provides relevant data to help evaluate the performance of these measures.

Objectives: To determine a suitable patch test concentration for five fragrance materials that had hitherto not been tested on a regular basis. These concentrations are then to be used in a surveillance study with patch testing consecutive patients over an extended monitoring period.

Materials And Methods: Furaneol, CAS.3658-77-3; trans-2-hexenal, CAS.6728-26-3; 4,8-dimethyl-4,9-decadienal, CAS.71077-31-1; longifolene, CAS.475-20-7; benzaldehyde, CAS.10052-7, were patch tested with other fragrance allergens in four clinics. Patch testing was conducted in three rounds, starting with the lowest concentrations of the five ingredients. The doses were increased in the subsequent rounds if no late-appearing positive reactions and virtually no irritant reactions were reported.

Results: Overall, 373 patients were tested. No positive allergic reaction was reported to the five ingredients. Patch test results of other fragrance allergens are reported.

Conclusions: The highest test concentrations are each considered safe for patch testing consecutive patients. Further surveillance based on these preparations will evaluate the hypothesis that QRA-driven consumer product levels of these fragrances can prevent sensitization.

Download full-text PDF

Source
http://dx.doi.org/10.1111/cod.14525DOI Listing

Publication Analysis

Top Keywords

patch testing
16
fragrance materials
8
materials hitherto
8
hitherto tested
8
patch test
8
testing consecutive
8
consecutive patients
8
fragrance allergens
8
patch
7
fragrance
5

Similar Publications

Purpose: The present study aimed to fabricate microneedles (MNs) for transdermal delivery of insulin. Chitosan-conjugated carboxy phenyl boronic acid polymer was synthesized and characterized to load insulin in the form of nanoparticles.

Methods: Optimized insulin nanoparticles (ILN-NPs) were loaded into MN arrays by micromolding, and the resulting MN patches were characterized by scanning electron microscopy (SEM) and mechanical failure tests.

View Article and Find Full Text PDF

ObjectiveThis study aims to determine the outcomes of nickel allergic patients who underwent a trial of forearm arterial stenting with a nickel-based stent, with follow-up to assess for an allergic reaction. In the absence of adverse effects, patients had their intracranial aneurysm treatment with a nickel-based cerebrovascular device.MethodsA retrospective analysis was performed on patients who had an allergy to nickel, with an intracranial aneurysm who underwent treatment with a permanently implanted nickel-containing device.

View Article and Find Full Text PDF

Artificial Intelligence in Contact Dermatitis: Current and Future Perspectives.

Dermatitis

September 2025

From the Department of Dermatology, Venereology and Leprology, All India Institute of Medical Sciences (AIIMS), Bhopal, India.

Contact dermatitis (CD), which includes both allergic CD and irritant CD, is a common inflammatory condition that can pose significant diagnostic challenges. Although patch testing is the gold standard for identifying causative allergens for allergic contact dermatitis (ACD), it is time-consuming, subjective, and requires expert interpretation. Recent advancements in artificial intelligence (AI), particularly in machine learning (ML) and deep learning, have shown promise in improving the accuracy, efficiency, and accessibility of CD diagnosis and management.

View Article and Find Full Text PDF

Boosting biocompatibility and minimizing inflammation in electrospun polyvinylidene fluoride (PVDF) cardiac patches through optimized low-pressure plasma treatment.

Biomater Adv

September 2025

Department of Applied Science and Technology (DISAT), Politecnico di Torino, Corso Duca Degli Abruzzi 24, 10129 Torino, Italy.

Tailoring surface characteristics is key to guiding scaffold interaction with the biological environment, promoting successful biointegration while minimizing immune responses and inflammation. In cardiac tissue engineering, polyvinylidene fluoride (PVDF) is a material of choice for its intrinsic piezoelectric properties, which can be enhanced through electrospinning, also enabling the fabrication of nanofibrous structures mimicking native tissue. However, the inherent hydrophobicity of PVDF can hinder its integration with biological tissues.

View Article and Find Full Text PDF

Transcatheter aortic valve replacement (TAVR) is a preferred treatment option for many patients with severe aortic stenosis, but concerns exist regarding safety in patients with nickel allergy due to metallic valve frames. We report a series of 7 patients with a history of nickel allergy who underwent TAVR. Preprocedural allergy evaluation varied, including patch testing or direct skin contact with valve fragments.

View Article and Find Full Text PDF