98%
921
2 minutes
20
Background/aims: Guide tube-assisted endoscopy for procedures that require repeated endoscopic access is safer and more effective than conventional endoscopy. However, its effectiveness has not been confirmed in animal studies. We assessed the usefulness of guide tube-assisted endoscopic procedures in an in vivo porcine model.
Methods: Five different guide tube-assisted endoscopic procedures were performed by experienced endoscopists on a pig weighing 32 kg. To evaluate the efficacy of these procedures, we compared the endoscopic approach time when a guide tube was used to that when it was not. Additional endoscopic procedures using a guide tube were performed, including multiple foreign body extractions, multiple polypectomies, and multiple submucosal dissections. To evaluate safety, we compared the insertion force into the proximal esophagus between the guide tube and conventional overtube methods.
Results: Using the endoscopic approach with a guide tube required a shorter average approach time to reach the three target lesions than when using the endoscopic approach without a guide tube (p<0.001). Compared to the conventional overtube method, the guide tube method produced a lower average resistance during insertion into the upper esophagus (p<0.001).
Conclusion: Guide tube-assisted endoscopic procedures are effective and safe for repeated endoscopic access in an in vivo porcine model.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10834288 | PMC |
http://dx.doi.org/10.5946/ce.2022.161 | DOI Listing |
Sleep Breath
September 2025
School of medicine, Università Campus Bio-Medico di Roma, Rome, Italy.
Introduction: It is well known that Obstructive Sleep Apnea (OSA) is a complex disease characterized by an Upper Airway (UA) collapse during sleep, with potential consequences on ENT districts. Recent evidence suggests a possible association with Eustachian Tube Dysfunction (ETD). However, the potential effects of both surgical and non-surgical therapeutic strategies on ET function remain poorly explored in the current literature.
View Article and Find Full Text PDFMed Eng Phys
October 2025
Department of Engineering Science, University of Oxford, United Kingdom. Electronic address:
Traditionally, clinical devices are designed, tested and improved through lengthy and expensive laboratory experiments and clinical trials [1]. More recently, computational methods have allowed for rapid testing, speeding up the design process and enabling far more complete searches of design space. While computational models cannot fully capture the complexities of biological systems, they provide valuable insights into crucial underlying mechanisms, such as the effects of fluid-structure interactions (FSIs).
View Article and Find Full Text PDFAnn Afr Med
September 2025
Department of Orthopaedics, Kasturba Medical College, Manipal, Manipal Academy of Higher Education, Manipal, Karnataka, India.
Introduction: Pediatric endotracheal intubation is challenging due to airway anatomical differences. Accurate endotracheal tube (ETT) sizing is crucial for effective ventilation and preventing complications. Traditional age, weight, or height-based methods are often unreliable, leading to multiple attempts.
View Article and Find Full Text PDFJ Telemed Telecare
September 2025
School of Medicine, The University of Queensland, St Lucia, QLD, Australia.
In this case, we describe the remote telehealth leadership of emergent tube thoracostomy in a patient with a critical respiratory status. The patient had presented to a small rural health care facility with breathlessness and hypoxia despite supplemental oxygen. A subsequent chest x-ray revealed a large pneumothorax requiring emergent treatment to prevent respiratory demise.
View Article and Find Full Text PDFJ Acute Med
September 2025
Rush University Medical Center Department of Emergency Medicine Chicago, IL USA.
Cardiac arrest is a common condition with low survival rates. Point-of-care ultrasound (POCUS) has been increasingly integrated in cardiac arrest care to enhance diagnostic accuracy and guide interventions. POCUS can be divided into cardiac and non-cardiac applications.
View Article and Find Full Text PDF