Article Abstract

The last several years have seen a rise in use of mechanical circulatory support (MCS) to bridge heart transplant recipients. A controlled hypothermic organ preservation system, the SherpaPak Cardiac Transport System (SCTS), was introduced in 2018 and has grown in utilization with reports of improved posttransplant outcomes. The Global Utilization And Registry Database for Improved heArt preservatioN (GUARDIAN)-Heart registry is an international, multicenter registry assessing outcomes after transplant using the SCTS. This analysis examines outcomes in recipients bridged with various MCS devices in the GUARDIAN-Heart Registry. A total of 422 recipients with donor hearts transported using SCTS were included and identified. Durable ventricular assist devices (VADs) were used exclusively in 179 recipients, temporary VADs or intra-aortic balloon pump (IABP) in 197, and extracorporeal membrane oxygenation (ECMO) in 14 recipients. Average ischemic times were over 3.5 hours in all cohorts. Severe primary graft dysfunction (PGD) posttransplant increased across groups (4.5% VAD, 5.1% temporary support, 21.4% ECMO), whereas intensive care unit (ICU) length of stay (18.2 days) and total hospital stay (39.4 days) was longer in the ECMO cohort than the VAD and IABP groups. A comparison of outcomes of MCS bridging in SCTS versus traditional ice revealed significantly lower rates of both moderate/severe right ventricular (RV) dysfunction and severe PGD in the SCTS cohort; however, upon propensity matching only the reductions in moderate/severe RV dysfunction were statistically significant. Use of SCTS in transplant recipients with various bridging strategies results in excellent outcomes.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11057488PMC
http://dx.doi.org/10.1097/MAT.0000000000002137DOI Listing

Publication Analysis

Top Keywords

transplant recipients
12
heart transplant
8
sherpapak cardiac
8
cardiac transport
8
transport system
8
guardian-heart registry
8
recipients
7
outcomes
6
scts
6
transplant
5

Similar Publications

Introduction: Differentiating acute tubular necrosis (ATN) from rejection in pediatric kidney transplant (KT) recipients remains challenging and necessitates invasive biopsy. Doppler ultrasound-derived resistive index (RI) is a noninvasive modality to assess graft status, but its diagnostic utility in children is unclear. This study evaluates RI's ability to distinguish ATN and rejection in KT.

View Article and Find Full Text PDF

Background: Tacrolimus is a commonly used immunosuppressant with well-defined side effects, including hypertriglyceridemia and hyperglycaemia. However, acute pancreatitis is still not widely recognized as an adverse event related to tacrolimus.

Case Presentation: A 60-year-old male was admitted to the intensive care unit with symptoms and signs of acute pancreatitis.

View Article and Find Full Text PDF

Background: Solid organ transplant (SOT) recipients are not only at increased risk of morbidity and mortality due to acute COVID-19 but may also experience poor long-term outcomes due to post-acute COVID-19 syndromes, including long COVID.

Methods: This retrospective, registry-based chart review evaluated graft failure and mortality among SOT recipients diagnosed with COVID-19 at a large, urban transplant center in Houston, Texas, USA. Patient populations were analyzed separately according to their long COVID status at the time of transplant to preserve the temporal relationship between the exposure (long COVID) and the outcome (graft failure or mortality).

View Article and Find Full Text PDF

Purpose: Acute graft-versus-host disease (aGVHD) is a significant cause of death in recipients of allogeneic hematopoietic stem cell transplantation. In this type of graft, the intestine is particularly affected, with the loss of intestinal barrier integrity playing a key role in its onset. In this scenario, the aim of the present research was to evaluate defibrotide, a heparin-like compound, marked for severe veno-occlusive disease, as an innovative therapeutic approach for restoring intestinal barrier integrity using an in vitro model and analyzing aGVHD patients' sera and clinical data.

View Article and Find Full Text PDF