98%
921
2 minutes
20
The exoscope serves as a valuable addition or alternative to traditional microscope systems in surgery, offering 3D visualization and magnification with enhanced maneuverability. In lateral femoral cutaneous nerve decompression for meralgia paresthetica, the exoscope is effective in identifying strictures of neural compression and minimizing iatrogenic nerve damage that may lead to improved pain management outcomes for patients. In this report, the specific case presented showcases how the exoscope aided in surgical decompression of the lateral femoral cutaneous nerve of a patient with refractory meralgia paresthetica with remote previous decompression and resultant scarring. The video can be found here: https://stream.cadmore.media/r10.3171/2023.10.FOCVID23162.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10821651 | PMC |
http://dx.doi.org/10.3171/2023.10.FOCVID23162 | DOI Listing |
J Craniofac Surg
September 2025
Department of Plastic and Reconstructive Surgery, Hanoi Medical University.
Introduction: Complex soft tissue injuries in the facial area can arise from various causes. Surgeons face significant challenges when reconstructing these injuries, as they must select appropriate materials based on texture and color, while also considering their composition and properties. The anterolateral thigh (ALT) flap has emerged as a versatile option in clinical reconstructive surgery, offering many advantages over other free flaps.
View Article and Find Full Text PDFJ Exp Orthop
July 2025
Department of Orthopedics and Traumatology Knee Surgery Group, School of Medical Sciences, Santa Casa of Sao Paulo Sao Paulo Sao Paulo Brazil.
Purpose: The objective of the study was to evaluate the accuracy of femoral tunnel positioning in the reconstruction of the anteromedial (AM) bundle of the Anterior Cruciate Ligament (ACL) using the most proximal and posterior portion of the lateral femoral condyle cartilage (Point C).
Methods: From December 2022 to December 2023, 47 patients underwent anterior cruciate ligament reconstruction (ACLR) in outside in manner using Point C as an anatomical landmark for AM bundle ACLR. After the procedure, the patients underwent tomographic evaluation to assess the accuracy of the positioning, using Bernard's quadrants.
Int Orthop
September 2025
University of Fukui, Fukui, Japan.
Background: Patients with secondary hip osteoarthritis due to developmental dysplasia of the hip (DDH) often have abnormal femoral morphology, making stem design critical for long-term outcomes. The FMS-anatomic stem previously demonstrated favourable mid-term results. Its successor, the Anatomic Fit stem, was developed with a reduced hydroxyapatite-coated area to enhance proximal load transfer and a narrower lateral flare to facilitate insertion.
View Article and Find Full Text PDFJ Arthroplasty
September 2025
Department of Orthopedics, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine University of Science and Technology of China, Hefei, Anhui 230001, China. Electronic address:
Background: Crowe type IV developmental dysplasia of the hip (DDH) presents unique challenges in total hip arthroplasty (THA). This study compares the clinical outcomes and efficiency of the direct anterior approach (DAA) in the lateral decubitus position combined with proximal femoral osteotomy (PFO) versus the postero-lateral approach (PLA).
Methods: A retrospective analysis of 73 hips from 64 patients who had Crowe type IV DDH was conducted.
J Am Acad Orthop Surg
August 2025
From the Department of Orthopedic Surgery (Kuttner), Ohio State University, Columbus, OH, the Department of Orthopedic Surgery (Cancio-Bello, Thompson, Sems, Cross, Hidden, Yuan), Mayo Clinic, Rochester, MN, and the Biomechanics Laboratory (Fitzsimmons, Berglund), Department of Orthopedic Surgery, M
Objectives: The Femoral Neck System (FNS) is a fixed-angle side plate device approved for use in fixation of femoral neck fractures. The FNS perforates the lateral cortex of the subtrochanteric femur, which may increase the risk of postoperative subtrochanteric fractures compared with the inverted triangle cannulated screw (CS) construct. The purpose of this biomechanical study was to compare forces required to create subtrochanteric fractures in FNS and CS constructs in a synthetic bone biomechanical model.
View Article and Find Full Text PDF