Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objective: In neurosurgery, posterior approaches intended at the craniovertebral junction are frequently used. The most popular procedures for treating upper cervical instability are C1 lateral mass, C2 pedicle, and C1-C2 transarticular screw stabilization. Due to their proximity to neural structures and the presence of the high-riding vertebral artery (VA), these techniques are complicated. The risk of VA damage can be decreased by mobilizing the VA. Using cadaveric specimens in this study was aimed to demonstrate C2 pedicle and C1-C2 transarticular screw placement with VA mobilization and a novel C2 inferior corpus screw placement technique.

Methods: In this study, twelve adult cadaveric specimens and two adult dry cadaveric C2 bones were used with the permission and decision of the University Research Ethics Committee. Colored silicone was injected into the arteries and veins of these twelve cadaveric specimens. Then, muscle dissection was performed stepwise, and the C2 vertebrae of the cadavers were revealed with a surgical microscope. Each specimen and entire stages of the dissections were recorded photographically. After cadaver dissections, screw placement was performed with three different techniques. Finally, radiological imaging was done with fluoroscopy.

Results: After dissection, the lateral mass of the C2 vertebra was observed, and lateral to it, the transverse process and foramen were detected with the help of a hook. Next, the posterior wall of the VA groove was removed using a 1 mm thin plate Kerrison rongeur until the VA loop could partially be observed the VA. This enables us to find the top of the loop of the VA and mobilize it inferiorly using a dissector. Following this step, the C1-2 transarticular, C2 pedicle, and the novel C2 inferior corpus screw placement can be performed safely by directly visualizing the artery.

Conclusions: Due to the nearby neurologic and vascular structures, placing the C2 pedicle and C1-2 transarticular screw is a challenging procedure, especially in high-riding VA cases. However, it is possible to place the C2 pedicle, C1-2 transarticular, and novel C2 inferior corpus screw after the mobilization of the VA. This study aimed to show all of them together on a cadaver for the first time, to understand the anatomy of the C2 vertebra, and to use screw placement techniques to minimize the risk of complications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10805154PMC
http://dx.doi.org/10.4103/jcvjs.jcvjs_73_23DOI Listing

Publication Analysis

Top Keywords

screw placement
24
vertebral artery
12
transarticular screw
12
cadaveric specimens
12
novel inferior
12
inferior corpus
12
corpus screw
12
c1-2 transarticular
12
screw
9
placement techniques
8

Similar Publications

Objective: To determine if a novel robotic system has comparable positional and angular accuracy to that achievable with patient-specific guides (PSG) when used for transcondylar screw (TCS) placement in the canine humerus.

Study Design: Experimental laboratory study.

Sample Population: A total of 32 synthetic humeral models (16 per group).

View Article and Find Full Text PDF

Background: Lumbar spondylolisthesis (LS) is a spinal disorder that often necessitates surgical intervention. However, evidence on the comparative clinical value of robot-assisted full-endoscopic transforaminal lumbar interbody fusion (RA FE-TLIF) versus conventional FE-TLIF in early-grade (Grades I and II) LS remains limited, leaving uncertainty about its true clinical value in this patient population. This study aims to compare the clinical efficacy and safety of FE-TLIF with RA FE-TLIF in patients with Grade I and II LS.

View Article and Find Full Text PDF

The purpose of this study is to propose a standardized classification of minimally invasive cervical pedicle screw (MICEPS) fixation according to the levels instrumented and the extent of the construct, thereby facilitating reproducible surgical planning and technique. We developed a three-tiered MICEPS classification with a specific surgical algorithm based on anatomic levels and construct length: Type 1, subaxial cervical fixation; Type 2, subaxial cervical to proximal thoracic fixation; and Type 3, subaxial cervical to T3/4 cervicothoracic stabilization. All techniques employ O-arm intraoperative navigation and preserve posterior tension-band integrity.

View Article and Find Full Text PDF

Purpose: To evaluate current surgical and prosthetic concepts in adult patients requiring complete tooth extraction for immediate implant placement and restoration in full-arch situations.

Materials And Methods: A narrative review was conducted using a comprehensive search strategy on MEDLINE via PubMed based on the PIO question to identify studies published up to October 2024. Data on treatment strategies, survival and success rates, marginal bone loss (MBL), peri-implant health, patient satisfaction, and quality of life (QoL) were extracted and synthesized.

View Article and Find Full Text PDF

Purpose: This scoping review describes the current evidence on immediate implant placement (IIP) and immediate restoration (IR) in single-unit and multiple-unit fixed dental prostheses regarding anatomical, surgical, and prosthetic factors.

Materials And Methods: Electronic searches were conducted in PubMed, Embase, and Cochrane databases for systematic reviews on IIP and IR in the anterior and posterior regions of the jaws. Bibliometric data and study details were extracted.

View Article and Find Full Text PDF