Toward Digital Twin Development for Implant Placement Planning Using a Parametric Reduced-Order Model.

Bioengineering (Basel)

Department of Digital Manufacturing, Hanbat National University, 125 Dongseo-daero, Yuseong-gu, Daejeon 34158, Republic of Korea.

Published: January 2024


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Real-time stress distribution data for implants and cortical bones can aid in determining appropriate implant placement plans and improving the post-placement success rate. This study aims to achieve these goals via a parametric reduced-order model (ROM) method based on stress distribution data obtained using finite element analysis. For the first time, the finite element analysis cases for six design variables related to implant placement were determined simultaneously via the design of experiments and a sensitivity analysis. The differences between the minimum and maximum stresses obtained for the six design variables confirm that the order of their influence is: Young's modulus of the cancellous bone > implant thickness > front-rear angle > left-right angle > implant length. Subsequently, a one-dimensional (1-D) CAE solver was created using the ROM with the highest coefficient of determination and prognosis accuracy. The proposed 1-D CAE solver was loaded into the Ondemand3D program and used to implement a digital twin that can aid with dentists' decision making by combining various tooth image data to evaluate and visualize the adequacy of the placement plan in real time. Because the proposed ROM method does not rely entirely on the doctor's judgment, it ensures objectivity.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10813277PMC
http://dx.doi.org/10.3390/bioengineering11010084DOI Listing

Publication Analysis

Top Keywords

implant placement
12
digital twin
8
parametric reduced-order
8
reduced-order model
8
stress distribution
8
distribution data
8
rom method
8
finite element
8
element analysis
8
design variables
8

Similar Publications

The impact of surgeons' visual angle misperception on acetabular cup positioning accuracy: a retrospective multicentre cohort study.

Int J Surg

September 2025

Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, People's Republic of China.

Background: Precise acetabular cup placement in total hip arthroplasty (THA) heavily relies on surgeons' visual judgment of angles. However, whether inherent visual angle misperception among surgeons affects surgical outcomes remains unclear. This study is the first to reveal that surgeons universally exhibit visual angle misperception, a key factor causing the cup implant positioning deviations in THA.

View Article and Find Full Text PDF

Rapid Atrial Pacing After TAVI for Pacemaker Prediction.

Rev Cardiovasc Med

August 2025

Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel - Vrije Universiteit Brussel, European Reference Networks Guard-Heart, 1090 Brussels, Belgium.

Despite continued advancements in transcatheter aortic valve implantation (TAVI) techniques, the incidence of permanent pacemaker implantation (PPI) remains substantial. Established predictors of PPI include advanced age, pre-existing electrocardiographic conduction abnormalities, prosthetic valve type, implantation depth, and anatomical parameters, such as membranous septum length, which are currently under active investigation. In routine clinical practice, the management strategy often involves the temporary placement of a transvenous pacemaker lead, followed by a period of observation.

View Article and Find Full Text PDF

Background Breast augmentation surgery (BAS) is one of the top cosmetic surgical procedures performed in the United States every year. There are various breast implant options, such as saline, silicone, smooth, and textured implants. Breast implant illness (BII) is a disorder associated with a wide array of symptoms presenting post breast implant surgery and is often associated with autoimmune disorders.

View Article and Find Full Text PDF

Transcrestal sinus augmentation has emerged as a minimally invasive alternative to lateral window techniques for vertical bone augmentation in the edentulous maxilla. Since its early introduction and modification over the last several decades, this technique has demonstrated predictable outcomes for implant placement in regions with limited bone height. This narrative review examines the current understanding and evolution of transcrestal sinus floor elevation (TSFE), focusing on factors related to long-term stability.

View Article and Find Full Text PDF

Introduction: anatomical deformities such as developmental dysplasia of the hip (DDH) and Perthes disease represent a challenge for reconstruction. The use of 3D-printed models can be helpful for assessing the deformity, bone mass, implant size, and orientation.

Objectives: to prospectively evaluate the outcomes of 3D simulation in primary total hip arthroplasty.

View Article and Find Full Text PDF