A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Single substrate-functionalized molybdenum oxide nanozyme for specific colorimetric monitoring of xanthine oxidase activity. | LitMetric

Single substrate-functionalized molybdenum oxide nanozyme for specific colorimetric monitoring of xanthine oxidase activity.

Mikrochim Acta

Institute of Biomedical Engineering, College of Life Sciences, School of Tourism and Geography Sciences, Qingdao University, Qingdao, 266071, China.

Published: January 2024


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Xanthine-functionalized molybdenum oxide nanodots (X-MoO NDs) with peroxidase (POD)-like activity were developed for selective, sensitive, and facile colorimetric quantification of xanthine oxidase (XO). Xanthine functionalization can not only be favorable for the successful nanozyme preparation, but also for the specific recognition of XO as well as the simultaneous generation of hydrogen peroxide, which was subsequently transformed into hydroxyl radical to oxidize the chromogenic reagent based on the POD-like catalysis. Under the optimized conditions, the colorimetric biosensing platform was established for XO assay without addition of further substrates, showing good linearity relationship between absorbance difference (ΔA) and XO concentrations in the range 0.05-0.5 U/mL (R = 0.998) with a limit of detection (LOD) of 0.019 U/mL. The quantification of XO occurs in 25 min, which is superior to the previously reported and commercial XO assays. The proposed method has been successfully used in the assay of human serum samples, showing its high potential in the field of clinical monitoring.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00604-023-06149-4DOI Listing

Publication Analysis

Top Keywords

molybdenum oxide
8
xanthine oxidase
8
single substrate-functionalized
4
substrate-functionalized molybdenum
4
oxide nanozyme
4
nanozyme specific
4
specific colorimetric
4
colorimetric monitoring
4
monitoring xanthine
4
oxidase activity
4

Similar Publications