Introduction: Despite advanced ablation strategies and major technological improvements, treatment of persistent atrial fibrillation (AF) remains challenging and the underlying pathophysiology is not fully understood. This study analyzed the multiple procedure outcome and safety of catheter ablation of spatiotemporal dispersions (DISPERS) detected by artificial intelligence (AI)-guided software in patients with long-standing persistent AF.
Methods And Results: The Volta VX1 software was used for 50 consecutive patients undergoing catheter ablation for persistent AF. First, high-density mapping (78% biatrial) with a multipolar mapping catheter was performed. In addition to pulmonary vein isolation (PVI), ablation of DISPERS was performed aiming at homogenizing, dissecting, isolating, or connecting DISPERS areas to nonconducting anatomical structures. Follow-up contained regular visits at our outpatient clinic at 1, 3, 6, and 12 months including 7-day Holter electrocardiograms. Patients were mainly suffering from long-standing persistent AF (mean AF duration 50.30 ± 54.28 months). Following PVI, ablation of left atrial and right atrial DISPERS areas led to AF cycle length prolongation (mean of 162.0 ± 16.6 to 202.2 ± 21.6 ms after) and AF termination to atrial tachycardia (AT) or sinus rhythm (SR) in 12 patients (24%). No stroke or pericardial effusion occurred; major groin complications (pseudoaneurysm n = 1, atrioventricular fistula n = 1) were detected in two patients. After a blanking period of 6 weeks, recurrence of any atrial arrhythmia was documented in 26 patients (52%). The majority of patients presented with organized AT (n = 15) while AF was present in n = 9 patients and AT/AF was observed in n = 2 patients. Twenty-two patients underwent reablation. During a mean follow-up of 363.14 ± 187.42 days and after an average of 1.46 ± 0.68 procedures, 82% of patients remained in stable SR.
Conclusion: DISPERS-guided ablation using machine learning software (the Volta VX1 software) in addition to PVI in long-standing persistent AF ablation resulted in high long-term success rates regarding AF and AT elimination. Most arrhythmia recurrences were reentrant AT. After a total of 1.46 ± 0.68 procedures, freedom from AF/AT was 82%. Despite prolonged procedure times complication rates were low. Randomized studies are necessary to evaluate long-term efficacy of dispersion-guided ablation using AI.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/jce.16184 | DOI Listing |
Heart Rhythm
September 2025
Translational Cardiology Group, Health Research Institute, Santiago de Compostela, Spain; CIBERCV, Madrid, España. Electronic address:
Background: High % of low-voltage area (LVA), a surrogate of scar, is associated with atrial fibrillation (AF) recurrence after pulmonary vein isolation (PVI). Noninvasive biomarkers of LVA are a medical need for PVI decision.
Objective: We aimed to identify the proteome profile of plasma extracellular vesicles (EVs) associated with high % LVA, their cellular origin, and their regulation by hyperglycemia.
Heart Rhythm O2
August 2025
Division of Cardiology, Tokyo Metropolitan Ohkubo Hospital, Shinjyuku-ku, Tokyo, Japan.
Background: Various methods have been devised for catheter ablation of persistent atrial fibrillation (AF). However, it remains difficult to understand the mechanism of AF and to determine the optimal method.
Objective: This study aimed to evaluate the effectiveness of rotor modification (RM) compared to posterior wall isolation (PWI) in the treatment of persistent AF.
J Egypt Natl Canc Inst
September 2025
National Cancer Institute of Cairo University, Giza, Egypt.
Objectives: To balance the extended functional urinary voiding and morbidity outcomes amid Ileal W and Y-shaped contrasted to spherical ileocoecal (IC) orthotopic bladders subsequent prostate-sparing radical cystectomy (PRC) versus standard radical cystoprostatectomy (RC).
Material And Methods: Two hundred eight male bladder cancer patients were grouped into 98 RC followed by 43-W, 31-Y, and 23-IC in comparison to 110 PRC followed by 35-W, 37-Y, and 38-IC. The functional voiding outcomes were determined by detailed patients' interview and urodynamic studies (UDS).
J Innov Card Rhythm Manag
August 2025
Department of Cardiology, University School of Medicine, Omaha, NE, USA.
Conduction system pacing has emerged as a new pacing technique to achieve cardiac physiologic pacing, but its utility and safety in patients with atrial fibrillation undergoing simultaneous ablation of the atrioventricular node remains seemingly unknown. Here, we present a case series of 10 patients with long-standing persistent or permanent atrial fibrillation who failed rate-control therapy and elected to proceed with simultaneous ablation of the atrioventricular node and His-bundle pacemaker implantation.
View Article and Find Full Text PDFCase Rep Psychiatry
August 2025
Mental Health Liaison Team, North Bristol NHS Trust, Bristol, UK.
Body integrity dysphoria (BID) is a rare disorder, in which individuals experience a persistent desire to become physically disabled, often through limb amputation. It is now included within the International Classification of Diseases 11th Revision (ICD-11), and this is one of the first case reports to describe the application of these new diagnostic criteria. This also raises the question of treatment pathways for individuals with the disorder, with recognition bringing legitimacy to patients' experience, and responsibility to professionals.
View Article and Find Full Text PDF