Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Accurate and continuous bladder volume monitoring is crucial for managing urinary dysfunctions. Wearable ultrasound (US) devices offer a solution by enabling noninvasive and real-time monitoring. Previous studies have limitations in power consumption and computation cost or quantitative volume estimation capability. To alleviate this, we present a novel pipeline that effectively integrates conventional feature extraction and deep learning (DL) to achieve continuous quantitative bladder volume monitoring efficiently. Particularly, in the proposed pipeline, bladder shape is coarsely estimated by a simple bladder wall detection algorithm in wearable devices, and the bladder wall coordinates are wirelessly transferred to an external server. Subsequently, a roughly estimated bladder shape from the wall coordinates is refined in an external server with a diffusion-based model. With this approach, power consumption and computation costs on wearable devices remained low, while fully harnessing the potential of DL for accurate shape estimation. To evaluate the proposed pipeline, we collected a dataset of bladder US images and RF signals from 250 patients. By simulating data acquisition from wearable devices using the dataset, we replicated real-world scenarios and validated the proposed method within these scenarios. Experimental results exhibit superior improvements, including +9.32% of IoU value in 2-D segmentation and -22.06 of RMSE in bladder volume regression compared to state-of-the-art (SOTA) performance from alternative methods, emphasizing the potential of this approach in continuous bladder volume monitoring in clinical settings. Therefore, this study effectively bridges the gap between accurate bladder volume estimation and the practical deployment of wearable US devices, promising improved patient care and quality of life.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TUFFC.2024.3350033DOI Listing

Publication Analysis

Top Keywords

bladder volume
24
volume monitoring
16
wearable devices
16
bladder
10
wearable ultrasound
8
ultrasound devices
8
shape estimation
8
continuous bladder
8
power consumption
8
consumption computation
8

Similar Publications

Background: High-dose-rate (HDR) brachytherapy is essential in the treatment of locally advanced cervical cancer. While Iridium-192 (Ir-192) is commonly used, its short half-life imposes logistical and financial constraints, particularly in low- and middle-income countries (LMICs). Cobalt-60 (Co-60), with a longer half-life and lower operational costs, is a viable alternative.

View Article and Find Full Text PDF

Purpose Of Review: The expanding range of minimally invasive surgical therapies (MISTs) for benign prostatic hyperplasia (BPH) reflects a growing emphasis on individualized, anatomy-driven treatment that prioritizes symptom relief, reduced morbidity, and preservation of sexual function. This review provides a timely synthesis of MISTs, highlighting innovations in technique, key anatomical considerations, and evolving strategies for patient-centered care in the modern clinical setting.

Recent Findings: Recent studies highlight the expanding role of MISTs, such as UroLift, Rezūm, the temporary implanted nitinol device, Optilume BPH, transperineal laser ablation, and prostatic stents.

View Article and Find Full Text PDF

Background: Bladder outlet obstruction (BOO) due to benign prostatic hyperplasia (BPH) is a common urological condition in aging men, often requiring surgical intervention for symptom relief.

Objective: To evaluate the therapeutic efficacy and complication profile of monopolar transurethral resection of the prostate (TURP) in patients with BOO.

Methodology: This descriptive observational study was conducted at the Department of Urology, Hayatabad Medical Complex, Peshawar, and Akhtar Saeed Trust Hospital, Lahore, from August 2022 to July 2024.

View Article and Find Full Text PDF

Background: Benign prostatic hyperplasia (BPH) is a common condition, particularly among high-risk patients who are unsuitable for surgical intervention due to comorbidities or anticoagulant use. Bipolar radiofrequency ablation is a minimally invasive technique that has been studied for its potential safety and efficacy. This study aimed to investigate the effectiveness of bipolar radiofrequency ablation in treating BPH and to identify the factors influencing the procedural success in high-risk patients.

View Article and Find Full Text PDF

Urinary bladder cancer contributes significantly to the global cancer burden and is more prevalent in the developed world. We present the case of a 54-year-old male smoker who underwent transurethral resection of bladder tumor and consequent trimodality therapy (induction chemotherapy followed by concomitant chemo-radiotherapy). His disease was staged at cT3N0M0.

View Article and Find Full Text PDF