98%
921
2 minutes
20
Background: Intracardiac echocardiography (ICE) represents a valuable image integration technique, with the unique advantage of dynamic real-time scar characterization.
Objectives: The goals of this study were to assess the correlation between ICE-defined and electroanatomic mapping (EAM)-defined scar in patients with ischemic cardiomyopathy and to define the outcomes of ICE-guided ventricular tachycardia (VT) ablation.
Methods: Thirty-eight patients with ischemic cardiomyopathy (SOUNDSCAR cohort) underwent full left ventricular (LV) ICE imaging and EAM. ICE-defined scar parameters (end-diastolic and end-systolic wall diameter [EDWD and ESWD], end-systolic wall thickening [percentage difference between EDWD and ESWD with respect to EDWD], slope [end-diastole to end-systole wall thickening], and American Heart Association wall motion scoring) were correlated with EAM-defined scar (voltage <1.5 mV). In a separate cohort (n = 21), outcomes of an ICE-guided VT ablation approach (EAM focused to ICE-defined scar regions) were compared with those of conventional ablation (full left ventricular mapping with EAM only; n = 21).
Results: In the 38 SOUNDSCAR patients (mean age 67 ± 11 years; 35 male [92%]; left ventricular ejection fraction 31% ± 10%; 2474 ICE segments; 524 ICE sectors), all ICE-defined parameters strongly predicted EAM-defined scar (area under the curve: American Heart Association score 0.873; ESWD 0.880; EDWD 0.827; slope 0.855; percentage difference between EDWD and ESWD with respect to EDWD, 0.851). All ICE-defined parameters had large effect sizes for predicting EAM-defined scar (logistic regression, P < .001). A detailed topographical comparison of ICE-defined (slope) and EAM-defined scar was possible in 25 patients and demonstrated 88% ± 10% overlap. Compared with conventional VT ablation, ICE-guided ablation was associated with shorter procedure times and comparable VT-free survival (ICE-guided vs conventional: procedure time 240 ± 20 minutes vs 298 ± 39 minutes; P < .001; VT recurrence 3 [14%] vs 7 [31%]; P = .19).
Conclusion: ICE-defined scar demonstrates a strong correlation with EAM-defined scar. ICE-guided VT ablation is associated with enhanced procedural efficiency.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.hrthm.2023.10.022 | DOI Listing |
Tohoku J Exp Med
September 2025
Department of Neurosurgery, Taihe Hospital Affiliated to Wannan Medical College.
Heart Rhythm
September 2025
Molecular Pharmacology and Physiology, Morsani College of Medicine, University of South Florida, Tampa, FL, United States. Electronic address:
Background: Electronic nicotine delivery systems (ENDS) utilize "E-liquids" in order to generate "E-vapor", an inhalable aerosolized mixture containing nicotine and flavors. Flavored ENDS are very popular among teens who vape, however, the possible cardiac electrophysiological harm of inhalation exposure to flavored ENDS are not fully understood.
Objective: To test if inhalation exposure to flavoring carbonyls in e-liquids compromises mitochondrial integrity, increases oxidative stress, and leads to cardiac electrophysiological toxicity.
J Physiol
September 2025
Department of Cell and Molecular Biology, University of Hawaii, Honolulu, HI, USA.
Diagnoses of prediabetes and metabolic syndromes, such as metabolic-associated steatotic liver disease (MASLD), are increasing at an alarming rate worldwide, often simultaneously. A significant consequence of these is high risk of cardiovascular disease, highlighting the need for cardiac-specific therapeutics for intervention during the prediabetic stage. Recent studies have demonstrated that chemogenetic activation of the cardiac parasympathetic system through hypothalamic oxytocin (OXT) neurons provides cardioprotective effects in heart disease models by targeting excitatory neurotransmission to brainstem cardiac vagal neurons.
View Article and Find Full Text PDFExp Physiol
September 2025
Unit of Cardiac Physiology, Division of Cardiovascular Sciences, Faculty of Biology, Medicine and Health, Manchester Academic Health Sciences Centre, 3.24 Core Technology Facility, University of Manchester, Manchester, UK.
The phosphodiesterase-5 inhibitor sildenafil suppresses ventricular arrhythmias in a sheep model of drug-induced long QT. In that study, ventricular arrhythmias were abolished by reducing premature ventricular complexes (PVCs) and delaying PVC onset, thus preventing 'R-on-T' ventricular tachycardia. Evidence for effects in humans with arrhythmias is lacking.
View Article and Find Full Text PDFRev Cardiovasc Med
August 2025
Department of Cardiology, Affiliated Hospital of Hangzhou Normal University, Zhejiang Key Laboratory of Medical Epigenetics, School of Basic Medical Sciences, Hangzhou Institute of Cardiovascular Diseases, Engineering Research Center of Mobile Health Management System&Ministry of Education, Hangzhou
Background: Depression is a highly prevalent mental disorder worldwide and is often accompanied by various somatic symptoms. Clinical studies have suggested a close association between depression and cardiac electrophysiological instability, particularly sudden cardiac death (SCD) and arrhythmias. Therefore, this review systematically evaluated the association between depression and the risks of SCD, atrial fibrillation (AF), and ventricular arrhythmias.
View Article and Find Full Text PDF