Background: Patients with chronic obstructive pulmonary disease (COPD) may be prescribed multiple inhalers that require different techniques for optimal performance. Mixing devices has been associated with poorer COPD outcomes suggesting that it leads to inappropriate inhaler technique. However, empirical evidence is lacking.
Aims: Compare the nature and frequency of dry powder inhaler (DPI) technique errors in patients with COPD using (1) a single DPI or (2) mixed-devices (a DPI and pressurised metered dose inhaler (pMDI)).
Methods: Data from the PIFotal study-a cross-sectional study on Peak Inspiratory Flow in patients with COPD using a DPI as maintenance therapy, capturing data from 1434 patients on demographic characteristics, COPD health status and inhaler technique-were used to select 291 patients using mixed-devices. Frequency matching based on country of residence and DPI device type was used to select 291 patients using a DPI-only for comparison. Predetermined checklists were used for the evaluation of DPI video recordings and complemented with additional errors that were observed in ≥10%. Error proportions were calculated for the (1) individual and total number of errors, (2) number of critical errors and (3) number of pMDI-related errors.
Results: The study sample contained 582 patients (mean (SD) age 69.6 (9.4) years, 47.1% female). DPI technique errors were common, but not significantly different between the groups. The majority of patients made at least one critical error (DPI-only: 90.7% vs mixed-devices: 92.8%). Proportions of total, 'pMDI-related' and critical errors did not significantly differ between the groups.
Conclusion: The nature and frequency of inhaler technique errors did not substantially differ between patients prescribed with a single DPI and mixed-devices. Currently, 'pMDI-related errors' in DPI use are not accounted for in existing checklists.
Trial Registration Number: ENCEPP/EUPAS48776.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1136/bmjresp-2023-001821 | DOI Listing |
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10749043 | PMC |
JMIR Form Res
September 2025
Department of Emergency Medicine, College of Medicine, National Taiwan University Hospital, Taipei, Taiwan.
Background: Hospital falls represent a persistent and significant threat to safety within health care systems worldwide, impacting both patient well-being and the occupational health of health care staff. While patient falls are a primary concern, addressing fall risks for all individuals within the health care environment remains a key objective. Caregiver visibility and spatial monitoring are recognized as crucial considerations in mitigating fall-related incidents.
View Article and Find Full Text PDFJ Chem Inf Model
September 2025
Department of Chemistry, Delaware State University, Dover, Delaware 19901, United States.
The calculation of the highest occupied molecular orbital-lowest unoccupied molecular orbital (HOMO-LUMO) gap for chemical molecules is computationally intensive using quantum mechanics (QM) methods, while experimental determination is often costly and time-consuming. Machine Learning (ML) offers a cost-effective and rapid alternative, enabling efficient predictions of HOMO-LUMO gap values across large data sets without the need for extensive QM computations or experiments. ML models facilitate the screening of diverse molecules, providing valuable insights into complex chemical spaces and integrating seamlessly into high-throughput workflows to prioritize candidates for experimental validation.
View Article and Find Full Text PDFJ Cataract Refract Surg
July 2025
Department of Ophthalmology, West China Hospital of Sichuan University, Chengdu City, Sichuan Province, China.
Purpose: To develop and validate a multimodal deep-learning model for predicting postoperative vault height and selecting implantable collamer lens (ICL) sizes using Anterior Segment Optical Coherence Tomography (AS-OCT) and Ultrasound Biomicroscope (UBM) images combined with clinical features.
Setting: West China Hospital of Sichuan University, China.
Design: Deep-learning study.
J Chem Theory Comput
September 2025
Department of Chemistry, Virginia Tech, Blacksburg, Virginia 24060, United States.
The Slater-type F12 geminal length scales originally tuned for the second-order Mo̷ller-Plesset F12 method are too large for higher-order F12 methods formulated using the SP (diagonal fixed-coefficient spin-adapted) F12 ansatz. The new geminal parameters reported herein reduce the basis set incompleteness errors (BSIEs) of absolute coupled-cluster singles and doubles F12 correlation energies by a significant─and increase with the cardinal number of the basis─margin. The effect of geminal reoptimization is especially pronounced for the cc-pVZ-F12 basis sets (specifically designed for use with F12 methods) relative to their conventional aug-cc-pVZ counterparts.
View Article and Find Full Text PDFBioinformatics
September 2025
Department of Biostatistics, University of Pittsburgh, Pittsburgh, Pennsylvania United States.
Summary: Causal mediation analysis investigates the role of mediators in the relationship between exposure and outcome. In the analysis of omics or imaging data, mediators are often high-dimensional, presenting challenges such as multicollinearity and interpretability. Existing methods either compromise interpretability or fail to effectively prioritize mediators.
View Article and Find Full Text PDF