Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Neural recordings frequently get contaminated by ECG or pulsation artifacts. These large amplitude components can mask the neural patterns of interest and make the visual inspection process difficult. The current study describes a sparse signal representation strategy that targets to denoise pulsation artifacts in local field potentials (LFPs) recorded intraoperatively. To estimate the morphology of the artifact, we first detect the QRS-peaks from the simultaneously recorded ECG trace as an anchor point. After the LFP data has been epoched with respect to each beat, a pool of raw data segments of a specific length is generated. Using the K-singular value decomposition (K-SVD) algorithm, we constructed a data-specific dictionary to represent each contaminated LFP epoch in a sparse fashion. Since LFP is aligned to each QRS complex and the background neural activity is uncorrelated to the anchor points, we assumed that constructed dictionary will be formed to mainly represent the pulsation artifact. In this scheme, we performed an orthogonal matching pursuit to represent each LFP epoch as a linear combination of the dictionary atoms. The denoised LFP data is thus obtained by calculating the residual between the raw LFP and its approximation. We discuss and demonstrate the improvements in denoised data and compare the results with respect to principal component analysis (PCA). We noted that there is a comparable change in the signal for visual inspection to observe various oscillating patterns in the alpha and beta bands. We also see a noticeable compression of signal strength in the lower frequency band (<13 Hz), which was masked by the pulsation artifact, and a strong increase in the signal-to-noise ratio (SNR) in the denoised data.Clinical Relevance- Pulsation artifact can mask relevant neural activity patterns and make their visual inspection difficult. Using sparse signal representation, we established a new approach to reconstruct the quasiperiodic pulsation template and computed the residue signal to achieve noise-free neural activity.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10746292PMC
http://dx.doi.org/10.1109/EMBC40787.2023.10340160DOI Listing

Publication Analysis

Top Keywords

pulsation artifact
8
local field
8
field potentials
8
sparse signal
8
data-specific dictionary
8
pulsation artifacts
8
visual inspection
8
lfp data
8
lfp epoch
8
lfp
6

Similar Publications

Background: Aqueductal stenosis represents one of the most common causes of CSF intraventricular blockage and may lead to obstructive triventricular hydrocephalus. In rare cases, the spontaneous rupture of the third ventricular floor, known as spontaneous third ventriculostomy (STV), can occur.

Observations: The authors report an illustrative case of pseudo-STV in a 67-year-old man who presented with long-standing obstructive triventricular hydrocephalus.

View Article and Find Full Text PDF

Implementing counter-pulsation (CP) control in pulsatile extracorporeal membrane oxygenator (p-ECMO) systems offers a refined approach to mitigate risks commonly associated with conventional ECMOs. To attain CP between the p-ECMO and heart, accurate detection of heartbeats within blood pressure (BP) waveform data becomes imperative, especially in situations where measuring electrocardiograms (ECGs) are difficult or impractical. In this study, a cumulative algorithm incorporating filter-type neural networks was developed to distinguish heartbeats from other pulse signals generated by the p-ECMO, reflections, or motion artifacts in the BP data.

View Article and Find Full Text PDF

Introduction Artifacts caused by vascular pulsation manifest as periodically high signals in the phase direction, often overlapping the target area and hindering accurate observation. Traditionally, these artifacts have been mitigated using flow compensation and presaturation pulses. However, complete removal remains challenging owing to extended imaging times and the need to consider the specific absorption rate.

View Article and Find Full Text PDF

This study presents a novel data augmentation approach to improve deep learning (DL)-based segmentation for 3D phase-contrast magnetic resonance angiography (PC-MRA) images affected by pulsation artifacts. Augmentation was achieved by simulating pulsation artifacts through the addition of periodic errors in k-space magnitude. The approach was evaluated on PC-MRA datasets from 16 volunteers, comparing DL segmentation with and without pulsation artifact augmentation to a level-set algorithm.

View Article and Find Full Text PDF

Atrioventricular nodal reentrant tachycardia (AVNRT), the most common supraventricular tachycardia, occasionally present with transient ST-T changes mimicking ischemia, posing diagnostic challenges for patients. We report an 82-year-old woman with paroxysmal palpitations whose initial ECG demonstrated supraventricular tachycardia (154 bpm) accompanied by dynamic ST-segment elevation and T-wave inversion in leads I, II, aVL, and aVF, while lead III remained unaffected. Repositioning electrodes away from the right radial artery pulsation resolved these deviations, confirming their artifactual origin.

View Article and Find Full Text PDF