Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Background: An ablation catheter and a circular mapping catheter requiring a double transeptal puncture (TSP) for left atrial access have been conventionally used for atrial fibrillation (AF) ablation. Recently, different operators have combined a single transseptal puncture technique with 3D high-density mapping catheters for pulmonary vein isolation (PVI).
Objective: This study aims to compare two strategies, single vs. double TSP, regarding the duration of the procedure, radiation time, complication rates, and outcomes.
Methods: Retrospective analysis of a large cohort of consecutive patients that underwent first PVI with radiofrequency energy (RF), using a point-by-point strategy, with a 3D mapping system, either with single or double TSP, according to the operator's choice.
Results: 285 patients with a mean age of 59.5 ± 11.6 years (36.5% female, 67.7% paroxysmal AF) underwent a point-by-point catheter ablation with RF between July 2015 and March 2020. The mean CHA2DS2-VASc score was 1.7 ± 1.3. Single TSP was performed in 115 (40.3%) patients and double TSP in 170 (59.6%). The operator's experience (≥5 years of AF ablation procedures) was equally distributed among the two groups. The average procedure time (133 ± 31.7 min vs. 123 ± 35.5 min, for single and double TSP, respectively) did reach a statistical difference between both groups ( = 0.008), but there was a substantial advantage regarding fluoroscopy time (13 ± 6.3 min vs. 19 ± 9.1 min, for single and double TSP, respectively; < 0.001). Acute major complications present similar rates in both groups (2.6% vs. 2.3%, = 0.799). At the 2-year follow-up, both groups had a similar sinus rhythm maintenance rate (76.5% vs. 78.8%, = 0.646).
Conclusion: A simplified single-TSP technique using high-density multi-electrode 3D mapping is a safe and highly successful option for AF ablation. This approach yields a substantial reduction in fluoroscopy time, with the potential to avoid acute complications, compared to a conventional double-TSP strategy.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10701513 | PMC |
http://dx.doi.org/10.3389/fcvm.2023.1309900 | DOI Listing |