Article Abstract

The use of microfluidic paper-based analytical devices (μPADs) for aiding medical diagnosis is a growing trend in the literature mainly due to their low cost, easy use, simple manufacturing, and great potential for application in low-resource settings. Many important biomarkers (proteins, ions, lipids, hormones, DNA, RNA, drugs, whole cells, and more) and biofluids are available for precise detection and diagnosis. We have reviewed the advances μPADs in medical diagnostics have achieved in the last few years, focusing on the most common human biofluids (whole blood/plasma, sweat, urine, tears, and saliva). The challenges of detecting specific biomarkers in each sample are discussed, along with innovative techniques that overcome such limitations. Finally, the difficulties of commercializing μPADs are considered, and future trends are presented, including wearable devices and integrating multiple steps in a single platform.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bios.2023.115846DOI Listing

Publication Analysis

Top Keywords

microfluidic paper-based
8
paper-based analytical
8
analytical devices
8
devices μpads
8
biological fluids
4
fluids microfluidic
4
μpads
4
μpads advances
4
advances challenges
4
challenges future
4

Similar Publications

Microfluidic paper-based analytical devices for food spoilage detection: emerging trends and future directions.

Talanta

September 2025

Faculty of Applied Sciences, Ton Duc Thang University, Ho Chi Minh City, Viet Nam. Electronic address:

Food spoilage poses a global challenge with far-reaching consequences for public health, economic stability, and environmental sustainability. Conventional analytical methods for spoilage detection though accurate are often cost-prohibitive, labor-intensive, and unsuitable for real-time or field-based monitoring. Microfluidic paper-based analytical devices (μPADs) have emerged as a transformative technology offering rapid, portable, and cost-effective solutions for food quality assessment.

View Article and Find Full Text PDF

Metal nanoparticles (MNPs) have emerged as vital components in nanotechnology due to their unique ability to concentrate light at the nanoscale. This property makes them especially valuable in biosensing applications, where high sensitivity is essential. At the same time, cellulose-based materials like paper offer an affordable, widely available, and versatile platform, making them ideal for the development of paper-based microfluidic analytical devices (μPADs).

View Article and Find Full Text PDF

Disposble electrochemical aptasensors: From design strategies, signal amplification, to applications and future perspectives.

Talanta

September 2025

Department of Cardiology, Affiliated Huishan Hospital of Xinglin College, Nantong University, Wuxi Huishan District People's Hospital, Wuxi, 214187, China. Electronic address:

Disposable electrochemical aptasensors (DEAs) hold significant promise for different analyte detection across diverse fields, due to inherent advantages of rapid response, portability, low cost, and high sensitivity. This review systematically examines the design strategies, signal amplification methodologies, and recent advances in DEAs in the fields of environmental analysis, food safety monitoring, and medical diagnostics. Specifically, it critically evaluates construction strategies for screen-printed electrodes (SPEs) and paper-based electrodes, including substrate selection, ink formulations, and key fabrication techniques such as screen printing, inkjet printing, deposition methods, and direct-writing technologies.

View Article and Find Full Text PDF

Astringency, a complex oral sensation resulting from interactions between mucin and polyphenols, remains difficult to quantify in portable field settings. Therefore, quantifying the aggregation through interactions can enable the classification of the astringency intensity, and assessing the capillary action driven by the surface tension offers an effective approach for this purpose. This study successfully replicates tannic acid (TA)-mucin aggregation on a paper-based microfluidic chip and utilizes machine learning (ML) to analyze the resulting capillary flow dynamics.

View Article and Find Full Text PDF

Tear Film-Based Diagnostics and Emerging Tissue Engineering Approaches in Personalized Dry Eye Disease Management.

Semin Ophthalmol

August 2025

Centre for Ocular Regeneration, Brien Holden Eye Research Centre, Champalimaud Translational Centre for Eye Research, LV Prasad Eye Institute, Hyderabad, India.

Purpose: The dry eye disease(DED) is caused by many possible factors, manifesting classical symptoms such as irritation, pain, and visual disturbance, which can severely impact the quality of life.  This review aims to critically evaluate currently available point‑of‑care (POC) diagnostic kits for DED, focusing on osmolarity‑based and biomarker‑based assays, while exploring emerging technologies that promise better precision and personalized management.

Methods: A comprehensive literature survey (2010-2025) was undertaken using PubMed, Scopus, and Google Scholar to identify studies assessing DED pathophysiology, tear film biomarkers, and commercially available diagnostic systems.

View Article and Find Full Text PDF