Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Background: To compare the accuracy of nine intraocular lens (IOL) power calculation formulas, including three traditional formulas (SRK/T, Haigis, and Hoffer Q) and six new-generation formulas (Barrett Universal II [BUII], Hill-Radial Basis Function [RBF] 3.0, Kane, Emmetropia verifying optical [EVO], Ladas Super, and Pearl-DGS) in patients who underwent cataract surgery after acute primary angle closure (APAC).
Methods: In this retrospective cross-sectional study, 44 eyes of 44 patients (APAC) and 60 eyes of 60 patients (control) were included. We compared the mean absolute error, median absolute error (MedAE), and prediction error after surgery. Subgroup analyses were performed on whether axial length (AL) or preoperative laser peripheral iridotomy affected the postoperative refractive outcomes.
Results: In the APAC group, all formulas showed higher MedAE and more myopic shift than the control group (all P < 0.05). In APAC eyes with AL ≥ 22 mm, there were no differences in MedAEs according to the IOL formulas; however, in APAC eyes with AL < 22 mm, Haigis (0.49 D) showed lower MedAE than SRK/T (0.82 D) (P = 0.036) and Hill-RBF 3.0 (0.54 D) showed lower MedAE than SRK/T (0.82 D), Hoffer Q (0.75 D) or Kane (0.83 D) (P = 0.045, 0.036 and 0.027, respectively). Pearl-DGS (0.63 D) showed lower MedAE than Hoffer Q (0.75 D) and Kane (0.83 D) (P = 0.045 and 0.036, respectively). Haigis and Hill-RBF 3.0 showed the highest percentage (46.7%) of eyes with PE within ± 0.5 D in APAC eyes with AL < 22 mm. Iridectomized eyes did not show superior precision than the non-iridotomized eyes in the APAC group.
Conclusions: Refractive errors in the APAC group were more myopic than those in the control group. Haigis and Hill-RBF 3.0 showed high precision in the eyes with AL < 22 mm in the APAC group.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10675974 | PMC |
http://dx.doi.org/10.1186/s12886-023-03232-5 | DOI Listing |