Article Abstract

Purpose: Studies have shown that double-inversion-recovery (DIR) prepared dark-blood T2*-weighted images result in lower SNR, CNR and diagnostic accuracy for intramyocardial hemorrhage (IMH) detection compared to non-DIR-prepared (bright-blood) T2*-weighted images; however, the mechanism contributing to this observation has not been investigated and explained in detail. This work tests the hypothesis that the loss of SNR on dark-blood cardiac T2*-weighted images of IMH stems from spin-relaxation during the long RF pulses in double inversion preparation, as a result, compromising image contrast for intramyocardial hemorrhage detection.

Methods: Phantom and in-vivo animal studies were performed to test the hypothesis of the study. An agar phantom was imaged with multi-gradient-echo T2* imaging protocols with and without double-inversion-recovery (DIR) preparation. Image acquisitions were placed at different delay times (TD) after DIR preparation. SNR, T2* and Coefficient of Variation (COV) were measured and compared between DIR-prepared and non-DIR-prepared images. Canines with hemorrhagic myocardial infarctions were scanned at 3.0 T with DIR-prepared (dark-blood) and non-DIR-prepared (bright-blood) T2* imaging protocols. DIR-prepared T2* images were acquired with short, medium, and long delay times (TD). SNR, CNR, intramyocardial hemorrhage (IMH) extent, T2* and COV were measured and compared between DIR-prepared T2* images with short, medium, and long delay times (TD) to non-DIR-prepared bright-blood T2* images.

Results: Phantom studies confirmed the hypothesis that the SNR loss on DIR-prepared T2* images originated from signal loss during DIR preparation. SNR followed T1 recovery curve with increased delay times (TD) indicating that SNR can be recovered with longer time delay between DIR and image acquisition. Myocardial T2* values were not affected by DIR preparation but COV of T2* was elevated. Animal studies supported the hypothesis and showed that DIR-prepared T2* images with insufficient delay time (TD) had impaired sensitivity for IMH detection due to lower SNR and CNR, and higher COV.

Conclusion: We conclude that lower SNR and CNR on DIR-prepared T2* images originate from signal loss during DIR preparation and insufficient recovery between DIR preparation and image acquisition. Although, the impaired sensitivity can be recovered by extending delay time (TD), it will extend the scan time. Bright-blood T2* imaging protocols should remain the optimal choice for assessment of intramyocardial hemorrhage. DIR-prepared dark-blood T2* imaging protocols should be performed with extra attention on image signal-to-noise ratio when used for intramyocardial hemorrhage detection.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.mri.2023.11.010DOI Listing

Publication Analysis

Top Keywords

intramyocardial hemorrhage
24
dir preparation
24
dir-prepared t2*
20
t2* images
20
snr cnr
16
t2* imaging
16
imaging protocols
16
delay times
16
t2*
15
t2*-weighted images
12

Similar Publications

Purpose: Myocardial infarction (MI), the leading cause of human mortality, is induced by a sudden interruption of blood supply. Among various stem cell types, endothelial progenitor cells (EPCs) are novel and valid cell sources for the restoration of vascularization in the ischemic tissue. The present study aimed to evaluate the regenerative properties of EPCs in rodent models of MI.

View Article and Find Full Text PDF

Background: ST-elevation myocardial infarction (STEMI) is a major cardiac event that requires rapid reperfusion therapy. The same reperfusion mechanism that minimizes infarct size and mortality may paradoxically exacerbate further cardiac damage-a condition known as reperfusion injury. Oxidative stress, calcium excess, mitochondrial malfunction, and programmed cell death mechanisms make myocardial dysfunction worse.

View Article and Find Full Text PDF

Utilization of magnetic resonance imaging in the treatment of patients with acute myocardial infarction and intramyocardial hemorrhage.

J Cardiothorac Surg

August 2025

Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Third Hospital of Shanxi Medical University, Tongji Shanxi Hospital, Taiyuan, 030032, China.

Background: We assessed the diagnostic efficacy of magnetic resonance imaging (MRI) in patients with acute myocardial infarction (AMI).

Methods: In this study, 116 patients with acute myocardial infarction (AMI) underwent direct PCI intervention, admitted to our hospital between January 2018 and January 2021 were selected. Based on the presence of intramyocardial hemorrhage (IMH), they were divided into the IMH group and the non-IMH group.

View Article and Find Full Text PDF

Aims: In acute ST-segment elevation myocardial infarction, ischaemia and reperfusion lead to a cascade of myocardial injury that can be characterized by cardiac magnetic resonance (CMR) imaging, including coagulation necrosis, oedema, papillary muscle damage, microvascular obstruction, and intramyocardial haemorrhage. Conventional CMR protocols require multiple sequences to be performed and complicated analysis. This study evaluates SPOT-MAPPING, a sequence that acquires co-registered T2 maps and dual bright- and black-blood late gadolinium enhancement (LGE) images in a single scan.

View Article and Find Full Text PDF

Background: Advances in acute ST-elevation myocardial infarction (STEMI) care have substantially decreased in-hospital mortality; however, in absolute terms, in-hospital mortality still remains high. Reperfusion injury, particularly intramyocardial hemorrhage following primary percutaneous coronary intervention (PCI), is a major predictor of adverse cardiovascular outcomes in the long term, but whether it contributes to in-hospital mortality is not known.

Methods: We performed a multicenter study to investigate the use of post-PCI high-sensitivity cardiac troponin I (hs-cTn-I) as a diagnostic tool to identify hemorrhagic myocardial infarction (MI) by determining hourly hs-cTn-I thresholds (every hour up to 12 hours, and at 16, 20, 24, and 48 hours post-PCI).

View Article and Find Full Text PDF