98%
921
2 minutes
20
Background: Preoperative anemia is common in patients undergoing total hip arthroplasty (THA) and total knee arthroplasty (TKA). Several definitions of anemia have been described, with no clear consensus on the optimal one for preoperative screening. We hypothesized that depending on the definition used preoperatively, the proportion of anemic patients identified who would require a postoperative allogeneic blood transfusion would vary significantly.
Methods: A total of 681,141 patients were identified in a national database who underwent either THA or TKA. Preoperative anemia was classified according to the World Health Organization (WHO) definition, Cleveland Clinic (CC) definition, or race, age, and sex-specific definition described by Beutler et al in 2006. The optimal preoperative (OP) hemoglobin thresholds to predict perioperative transfusions were also calculated using receiver operating characteristic curves.
Results: When using the WHO definition, 18% of anemic patients required a transfusion versus 14% (OP definition), 12% (CC definition), and 16% (Beutler definition). Similarly, 0.69% of anemic patients sustained a periprosthetic joint infection within 30 days using the WHO definition versus 0.59% (OP definition), 0.60% (CC definition), or 0.66% (Beutler definition). Using the WHO definition, 5.3% of patients would have sustained a major complication versus 4.5% (OP definition), 4.4% (CC definition), and 5.0% (Beutler definition).
Conclusions: Variation in the definition of anemia for preoperative screening in THA and TKA results in substantial differences in discriminative ability to predict perioperative transfusions. The WHO definition identified the largest proportion of patients who ultimately received a perioperative transfusion.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.arth.2023.10.059 | DOI Listing |
Multimed Man Cardiothorac Surg
September 2025
Department of Thoracic Surgery, New Cross Hospital, Royal Wolverhampton NHS Trust, Wolverhampton, UK
Three-dimensional (3D) guided robotic-assisted thoracic surgery is increasingly recognized as the pioneering approach for the most complex of pulmonary resections, offering high-definition 3D visualization, enhanced instrument augmentation and tremor-free tissue articulation. Compared with open thoracotomy, the robotic platform is associated with reduced peri-operative morbidity, shorter hospital admissions and faster patient recovery. However, sublobar resections such as segmentectomies remain anatomically and technically demanding, particularly in the context of resecting multiple segments, as showcased in this right S1 and S2 segmentectomy.
View Article and Find Full Text PDFMultimed Man Cardiothorac Surg
September 2025
Department of Cardiothoracic Surgery, St George’s Hospital, St George's University Hospitals NHS Foundation Trust, London, UK
Three-dimensional (3D) guided robotic-assisted thoracic surgery is increasingly recognized as a leading technique for undertaking the most complex pulmonary resections, providing high-definition 3D visualization, advanced instrument control and tremor-free tissue handling. Compared with open thoracotomy, the robotic platform offers reduced peri-operative complications, shorter hospital stays and faster patient recovery. Nevertheless, sublobar resections, such as segmentectomies, remain both anatomically intricate and technically challenging, particularly when resecting multiple segments, as in this left S1 and S2 segmentectomy.
View Article and Find Full Text PDFJ Prosthodont
September 2025
Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.
Purpose: This study aimed to evaluate the inherent and after cyclic loading fracture strength of implant-supported cantilevered fixed prostheses fabricated from recently introduced additively manufactured (AM) and subtractively manufactured (SM) materials, considering variations in prosthesis height.
Materials And Methods: Three cylinder-shaped master files (20 mm long and 11 mm wide) with varying heights (7, 11, and 15 mm) and a titanium-base (Ti-base) abutment space were designed. These designs were used to fabricate a total of 144 specimens with two AM resins indicated for definitive use (Crowntec; AM-CT and Flexcera Smile Ultra+; AM-FS), one high-impact polymer composite (breCAM.
Appl Environ Microbiol
September 2025
Department of Environmental Microbiology, Eawag, Swiss Federal Institute of Aquatic Science and Technology, Dübendorf, Switzerland.
Unlabelled: The genus includes opportunistic pathogens inhabiting engineered aquatic ecosystems, where managing their presence and abundance is crucial for public health. In these environments, interact positively or negatively with multiple members of the microbial communities. Here, we identified bacteria and compounds with -antagonistic properties.
View Article and Find Full Text PDF