Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Postoperative atrial fibrillation (POAF) is a common complication after cardiac surgery and is associated with poor clinical outcomes. The objective of this systematic review and meta-analysis was to assess the performance of risk scores to predict POAF in cardiac surgery patients. We searched MEDLINE, Embase, and Cochrane CENTRAL for studies that developed/evaluated a POAF risk prediction model. Pairs of reviewers independently screened studies and extracted data. We pooled area under the receiver operating curves (AUCs), sensitivity and specificity, and adjusted odds ratios from multivariable regression analyses using the generic inverse variance method and random effects models. Forty-three studies (n = 63,847) were included in the quantitative synthesis. Most scores were originally developed for other purposes but evaluated for predicting POAF. Pooled AUC revealed moderate POAF discrimination for the EuroSCORE II (AUC 0.59, 95% confidence interval [CI] 0.54 to 0.65), Society of Thoracic Surgeons (AUC 0.60, 95% CI 0.56 to 0.63), EuroSCORE (AUC 0.63, 95% CI 0.58 to 0.68), CHADS (AUC 0.66, 95% CI 0.57 to 0.75), POAF Score (AUC 0.66, 95% CI 0.63 to 0.68), HATCH (AUC 0.67, 95% CI 0.57 to 0.75), CHADS-VASc (AUC 0.68, 95% CI 0.60 to 0.75) and SYNTAX scores (AUC 0.74, 95% CI 0.71 to 0.78). Pooled analyses at specific cutoffs of the CHADS-VASc, CHADS, HATCH, and POAF scores demonstrated moderate-to-high sensitivity (range 46% to 87%) and low-to-moderate specificity (range 31% to 70%) for POAF prediction. In conclusion, existing clinical risk scores offer at best moderate prediction for POAF after cardiac surgery. Better models are needed to guide POAF risk stratification in cardiac surgery patients.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.amjcard.2023.08.161DOI Listing

Publication Analysis

Top Keywords

cardiac surgery
20
risk scores
12
poaf
10
auc
9
postoperative atrial
8
atrial fibrillation
8
systematic review
8
review meta-analysis
8
poaf cardiac
8
surgery patients
8

Similar Publications

Background: Evidence informing clinical guidelines assumes that all transcatheter aortic valve implantation (TAVI) devices have similar effectiveness, in other words, displaying a class effect across TAVI valves. We aimed to assess the comparative effectiveness of different TAVI platforms relative to other TAVI counterparts or surgical aortic valve replacement (SAVR).

Methods: MEDLINE/Embase/CENTRAL were searched from inception until April 2025, for randomized controlled trials comparing outcomes with different commercially available TAVI devices relative to other TAVI counterparts or SAVR.

View Article and Find Full Text PDF

Robotic mitral repair is often associated with longer ischaemic and cardiopulmonary bypass times, particularly early in the learning curve. We demonstrate a semi-continuous, three-suture technique for robotic annuloplasty that retains the mechanical principles of traditional interrupted sutures while leveraging the advantages of robotic precision and exposure. The use of pre-knotted sutures minimizes intra-cardiac knot tying, further enhancing procedural efficiency.

View Article and Find Full Text PDF

A Novel Technique to Extract Implanted Leads Using Simple Stylets and Reused Rotational Sheaths in Patients with a Cardiac Implantable Electronic Device.

Turk Kardiyol Dern Ars

September 2025

Division of Arrhythmia and Electrophysiology, Department of Cardiology, University of Health Sciences, Yuksek Ihtisas Cardiovascular Building, Ankara City Hospital, Ankara, Türkiye.

Objective: Transvenous lead extraction (TLE) is used in various clinical scenarios, such as device-related infections. Mechanically powered sheaths are one of the most commonly used tools for TLE procedures. We evaluated the procedural and clinical outcomes of a novel extraction technique for chronically implanted leads in the treatment of device-related infections.

View Article and Find Full Text PDF

Objectives: This study aimed to evaluate the predictive accuracy of Paediatric Risk of Mortality-III, Paediatric Index of Mortality-II, and Paediatric Logistic Organ Dysfunction scoring systems for major adverse events following congenital heart surgery.

Methods: This prospective observational study included patients under 18 years of age who were admitted to the ICU for at least 24 hours postoperatively following congenital heart surgery. Major adverse events were defined as a composite of 30-day mortality, ICU readmission, reintubation, acute neurologic events, requirement for extracorporeal membrane oxygenation, cardiac arrest requiring cardiopulmonary resuscitation, need for a permanent pacemaker, acute kidney injury, or unplanned reoperation.

View Article and Find Full Text PDF

Standardising cardiac CT-based personalised surgical planning and execution in congenital aortic valvar disease.

Cardiol Young

September 2025

Congenital Valve Procedural Planning Program, Division of Pediatric Cardiac Surgery, Cleveland Clinic Children's, and Heart, Vascular, and Thoracic Institute, Cleveland Clinic, Cleveland, OH, USA.

Background: Congenital aortic valvar disease represents a heterogeneous population with suboptimal surgical repair or replacement outcomes. We assess our approach and short-term outcomes in this population using cardiac CT evaluation for personalised surgical planning and execution.

Methods: We assessed patients who underwent aortic valvar surgery from February 2022 to August 2024.

View Article and Find Full Text PDF