98%
921
2 minutes
20
We study the prospects of using quantum Monte Carlo techniques (QMC) to optimize the electronic wavefunctions and atomic geometries of gold compounds. Complex gold nanoclusters are widely studied for diverse biochemical applications, but the dynamic correlation and relativistic effects in gold set the bar high for reliable, predictive simulation methods. Here we study selected ground state properties of few-atom gold clusters by using density functional theory (DFT) and various implementations of the variational Monte Carlo (VMC) and diffusion Monte Carlo. We show that the QMC methods mitigate the exchange-correlation (XC) approximation made in the DFT approach: the average QMC results are more accurate and significantly more consistent than corresponding DFT results based on different XC functionals. Furthermore, we use demonstrate structural optimization of selected thiolated gold clusters with between 1 and 3 gold atoms using VMC forces. The optimization workflow is demonstrably consistent, robust, and its computational cost scales with nb, where b < 3 and n is the system size. We discuss the implications of these results while laying out steps for further developments.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1063/5.0174383 | DOI Listing |
Multivariate Behav Res
September 2025
Department of Social Psychology and Methodology, Universidad Autonoma de Madrid, Madrid, Spain.
Wording effects, the systematic method variance arising from the inconsistent responding to positively and negatively worded items of the same construct, are pervasive in the behavioral and health sciences. Although several factor modeling strategies have been proposed to mitigate their adverse effects, there is limited systematic research assessing their performance with exploratory structural equation models (ESEM). The present study evaluated the impact of different types of response bias related to wording effects (random and straight-line carelessness, acquiescence, item difficulty, and mixed) on ESEM models incorporating two popular method modeling strategies, the correlated traits-correlated methods minus one (CTC[M-1]) model and random intercept item factor analysis (RIIFA), as well as the "do nothing" approach.
View Article and Find Full Text PDFJ Chem Phys
September 2025
Department of Earth Sciences, University College London, London WC1E 6BT, United Kingdom.
Fixed-node diffusion quantum Monte Carlo (FN-DMC) is a widely trusted many-body method for solving the Schrödinger equation, known for its reliable predictions of material and molecular properties. Furthermore, its excellent scalability with system complexity and near-perfect utilization of computational power make FN-DMC ideally positioned to leverage new advances in computing to address increasingly complex scientific problems. Even though the method is widely used as a computational gold standard, reproducibility across the numerous FN-DMC code implementations has yet to be demonstrated.
View Article and Find Full Text PDFJ Chem Phys
September 2025
Theoretical Physics IV, University of Bayreuth, 95447 Bayreuth, Germany.
Density functional theory (DFT) is a cornerstone of modern electronic structure theory. In the Kohn-Sham scheme, the many-electron Schrödinger equation is replaced by a set of effective single-particle equations. Thus, the full complexity of the quantum mechanical many-particle effects is mapped to the exchange-correlation potential vxc(r).
View Article and Find Full Text PDFRep Pract Oncol Radiother
August 2025
Laboratory of Engineering in Chemistry and Physics of Matter (LICPM), Faculty of Sciences and Techniques, Sultan Moulay Slimane University, Beni-Mellal, Morocco.
Background: This study investigates the impact of voxel size on dose calculations for the FlexiSource iridium-192 (Ir) high-dose-rate brachytherapy source using the TOol for PArticle Simulation (TOPAS) Monte Carlo code. It aims to establish a new dataset for future research by determining TG-43 parameters.
Materials And Methods: TG-43 parameters (radial function and anisotropy function) were calculated using 0.
Cureus
August 2025
Department of Radiology, Aichi Medical University, Nagakute, JPN.
Purpose This planning study aimed to clarify the significance of inverse planning with variable dose rate (VDR) and the segment shape optimization (SSO) in the quality and efficiency of dynamic conformal arcs (DCA) using the high-definition dynamic radiosurgery (HDRS) platform for stereotactic radiosurgery (SRS) of single brain metastases (BMs). Materials and methods Twenty clinical BMs were included, with the gross tumor volume (GTV) ranging from 0.33 cc to 48.
View Article and Find Full Text PDF