Article Abstract

Purpose: The study evaluates the efficacy of cone-beam computed tomography (CBCT)-based synthetic CTs (sCT) as a potential alternative to verification CT (vCT) for enhanced treatment monitoring and early adaptation in proton therapy.

Methods: Seven common treatment sites were studied. Two sets of sCT per case were generated: direct-deformed (DD) sCT and image-correction (IC) sCT. The image qualities and dosimetric impact of the sCT were compared to the same-day vCT.

Results: The sCT agreed with vCT in regions of homogeneous tissues such as the brain and breast; however, notable discrepancies were observed in the thorax and abdomen. The sCT outliers existed for DD sCT when there was an anatomy change and for IC sCT in low-density regions. The target coverage exhibited less than a 5% variance in most DD and IC sCT cases when compared to vCT. The D of serial organ-at-risk (OAR) in sCT plans shows greater deviation from vCT than small-volume dose metrics (D0.1cc). The parallel OAR volumetric and mean doses remained consistent, with average deviations below 1.5%.

Conclusion: The use of sCT enables precise treatment and prompt early adaptation for proton therapy. The quality assurance of sCT is mandatory in the early stage of clinical implementation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10605451PMC
http://dx.doi.org/10.3390/cancers15205101DOI Listing

Publication Analysis

Top Keywords

sct
13
cone-beam computed
8
computed tomography
8
proton therapy
8
early adaptation
8
adaptation proton
8
applications pitfalls
4
pitfalls cone-beam
4
computed tomography-based
4
tomography-based synthetic
4

Similar Publications

Problem: Preeclampsia (PE) is a leading cause of perinatal maternal and fetal mortality. Clinical and pathological studies suggest that placental and decidual cell dysfunction may contribute to this condition. However, the pathogenesis of PE remains poorly understood.

View Article and Find Full Text PDF

Defect Engineering-Driven Electron Spin Polarization and Charge Transfer in MOFs for Enhanced Sonocatalytic Therapy.

Adv Mater

September 2025

Beijing Advanced Innovation Center for Soft Matter Science and Engineering, State Key Laboratory of Organic-Inorganic Composites, Bionanomaterials & Translational Engineering Laboratory, Beijing Key Laboratory of Bioprocess, Beijing Laboratory of Biomedical Materials, Beijing University of Chemical

Sonocatalytic therapy (SCT) is a non-invasive tumor treatment modality that utilizes ultrasound (US)- activated sonocatalysts to generate reactive oxygen species (ROS), whose production critically dependent on the electronic structural properties of the catalytic sites. However, the spin state, which is a pivotal descriptor of electronic properties, remains underappreciated in SCT. Herein, a Ti-doped zirconium-based MOF (Ti-UiO-66, denoted as UTN) with ligand-deficient defects is constructed for SCT, revealing the important role of the electronic spin state in modulating intrinsic catalytic activity.

View Article and Find Full Text PDF

Compared to adult cancer in Aboriginal and Torres Strait Islander populations, minimal research has focussed on cancer in Indigenous Australian children. This narrative review examined published information about incidence, mortality, barriers to diagnosis and treatment, and psychosocial needs and interventions for Indigenous Australian children with cancer. Most papers were epidemiological, investigating incidence and mortality.

View Article and Find Full Text PDF

Background: This study evaluates the quality of synthetic computed tomography (sCT) images for MR-only radiotherapy in prostate cancer using gamma analysis. A software tool, MRGamma, was developed to address challenges like the absence of electron density maps and registration uncertainties between magnetic resonance imaging (MRI) and planning CT (pCT).

Materials And Methods: Aplication developed in MATLAB assesses Hounsfield units (HU) discrepancies between CT and sCT images via 2D and 3D gamma analysis (GA).

View Article and Find Full Text PDF