A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Impact of slab selection on the relationship between choriocapillaris flow deficits and enlargement rate of geographic atrophy. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objective: To evaluate the effect of changing slab position on the correlation between choriocapillaris (CC) flow deficits (FD) in eyes with geographic atrophy (GA) and yearly enlargement rate (yER) of GA.

Methods: OCT and OCTA images obtained on Cirrus HD-OCT device were collected from patients with GA. Each patient underwent OCTA scan at baseline and two OCT scans, one at baseline and one after at least 12 months. GA was delineated on en-face fundus image to calculate yER. OCTA images were generated from three 10 µm thick slabs 11, 21 and 31 µm posterior to RPE-fit line. 100 µm-wide concentric rings were generated around GA to calculate FD% in each ring which was correlated with yER.

Results: For the 11-21 µm slab, FD% was not significantly correlated with yER for any of the rings (p > 0.05). For the 21-31 and 31-41 µm slab, FD% of rings located in the 600 µm region around GA was significantly correlated with yER (p < 0.05). However, in all slab locations, there was no significant correlation between yER and CC FD% of rings located beyond the 600 µm region (p > 0.05).

Conclusions: Slab selection for quantification of CC FD% may have a significant impact on quantitative results in eyes with GA.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10966059PMC
http://dx.doi.org/10.1038/s41433-023-02788-2DOI Listing