Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Magnetic resonance imaging (MRI) has been suggested as a tool for guiding biopsy recommendations in prostate cancer (PC) screening.

Objective: To determine the performance of multiparametric MRI (mpMRI) in young men at age 45 yr who participated in a PC screening trial (PROBASE) on the basis of baseline prostate-specific antigen (PSA).

Design, Setting, And Participants: Participants with confirmed PSA ≥3 ng/ml were offered mpMRI followed by MRI/transrectal ultrasound fusion biopsy (FBx) with targeted and systematic cores. mpMRI scans from the first screening round for men randomised to an immediate PSA test in PROBASE were evaluated by local readers and then by two reference radiologists (experience >10 000 prostate MRI examinations) blinded to the histopathology. The PROBASE trial is registered as ISRCTN37591328 OUTCOME MEASUREMENTS AND STATISTICAL ANALYSIS: The local and reference Prostate Imaging-Data and Reporting System (PI-RADS) scores were compared, and the sensitivity, negative predictive value (NPV), and accuracy were calculated for both readings for different cutoffs (PI-RADS 3 vs 4).

Results And Limitations: Of 186 participants, 114 underwent mpMRI and FBx. PC was detected in 47 (41%), of whom 33 (29%) had clinically significant PC (csPC; International Society of Urological Pathology grade group ≥2). Interobserver reliability between local and reference PI-RADS scores was moderate (k = 0.41). At a cutoff of PI-RADS 4, reference reading showed better performance for csPC detection (sensitivity 79%, NPV 91%, accuracy of 85%) than local reading (sensitivity 55%, NPV 80%, accuracy 68%). Reference reading did not miss any PC cases for a cutoff of PI-RADS <3. If PI-RADS ≥4 were to be used as a biopsy cutoff, mpMRI would reduce negative biopsies by 68% and avoid detection of nonsignificant PC in 71% of cases.

Conclusions: Prostate MRI in a young screening population is difficult to read. The MRI accuracy of for csPC detection is highly dependent on reader experience, and double reading might be advisable. More data are needed before MRI is included in PC screening for men at age 45 yr.

Patient Summary: Measurement of prostate specific antigen (PSA) is an effective screening test for early detection of prostate cancer (PC) and can reduce PC-specific deaths, but it can also lead to unnecessary biopsies and treatment. Magnetic resonance imaging (MRI) after a positive PSA test has been proposed as a way to reduce the number of biopsies, with biopsy only recommended for men with suspicious MRI findings. Our results indicate that MRI accuracy is moderate for men aged 45 years but can be increased by a second reading of the images by expert radiologists. For broad application of MRI in routine screening, double reading may be advisable.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.eururo.2023.09.027DOI Listing

Publication Analysis

Top Keywords

magnetic resonance
8
resonance imaging
8
prostate cancer
8
screening round
8
probase trial
8
local reference
8
pi-rads scores
8
cutoff pi-rads
8
reference reading
8
reference
5

Similar Publications

The global rise in antibiotic resistance demands the urgent development of new antibacterial agents. This study investigated the antibacterial potential of four synthesized methoxy and thiophene chalcone derivatives (designated 3a, 4a, 3b, and 4b) against clinically relevant bacterial pathogens. These compounds were prepared through Claisen-Schmidt condensation, while their chemical structures were verified through applying Fourier-transform infrared, mass spectrometry, H nuclear magnetic resonance (NMR), and C NMR.

View Article and Find Full Text PDF

Background And Objectives: While reductions in optical coherence tomography (OCT) pRNFL and ganglion cell-inner plexiform layer thicknesses have been shown to be associated with brain atrophy in adult-onset MS (AOMS) cohorts, the relationship between OCT and brain MRI measures is less established in pediatric-onset MS (POMS). Our aim was to examine the associations of OCT measures with volumetric MRI in a cohort of patients with POMS to determine whether OCT measures reflect CNS neurodegeneration in this patient population, as is seen in AOMS cohorts.

Methods: This was a cross-sectional study with retrospective ascertainment of patients with POMS evaluated at a single center with expertise in POMS and neuro-ophthalmology.

View Article and Find Full Text PDF

Fetal 4D Flow CMR for Advanced Diagnostics of Congenital Heart Disease: A Prospective Cohort Study.

Eur Heart J Cardiovasc Imaging

September 2025

Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany.

Aims: Fetal circulation undergoes complex changes in congenital heart disease (CHD) that are challenging to assess with fetal echocardiography. This study aimed to assess clinical feasibility and diagnostic value of 4D flow cardiac magnetic resonance (CMR) in fetal CHD.

Methods And Results: Pregnant women in advanced third trimester pregnancy with fetal CHD were prospectively recruited for fetal CMR between 08/2021 and 11/2024.

View Article and Find Full Text PDF

Soft tissue sarcomas are a heterogeneous group of malignancies arising from mesenchymal cells. Recent advancements in genomic profiling have identified novel gene fusions in these tumors, offering new insights into their pathogenesis and potential therapeutic targets. Here, we describe a spindle cell sarcoma harboring a novel gene fusion.

View Article and Find Full Text PDF

Ultrasmall MoC-MoO Heterojunction Coupled with Nitrogen-Doped Reduced Graphene for Boosting the Deep Oxidative Desulfurization of Fuel Oils.

Langmuir

September 2025

Engineering Technology Research Center of Preparation and Application of Industrial Ceramics of Anhui Province, Engineering Research Center of High-frequency Soft Magnetic Materials and Ceramic Powder Materials of Anhui Province, School of Chemistry and Material Engineering, Chaohu University, Chaoh

In this study, a MoC-MoO@NCrGO-900 composite catalyst comprising two-dimensional nitrogen-doped reduced graphene oxide (NCrGO) and ultrasmall molybdenum carbide-molybdenum dioxide (MoC-MoO) heterojunctions was synthesized. The optimized catalyst exhibited an outstanding oxidative desulfurization (ODS) performance. Specifically, a model oil containing 4000 ppm sulfur was completely desulfurized within 30 min, with a desulfurization efficiency of 98.

View Article and Find Full Text PDF