A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Design and development of a lanthanide-labeled immunochromatographic strip for simultaneous detection of morphine, methamphetamine and ketamine in hair. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Colloidal gold immunoassay is the most widely used method in the field of drug detection. However, this method often has poor quantitative identification ability and low analytical sensitivity, which is not suitable for the analysis of hair poisoning ingredients. In order to solve these limitations, we developed an immunochromatographic test strip for simultaneously screening multiple drugs in this study. This hand-held test strip used fluorescent nanoparticles loaded with lanthanide chelates as the signal carrier of fluorescence reading, and conducted quantitative testing of various drugs based on the competitive immune reaction between the analyte and antigen. Under the optimal conditions, the competition curves of morphine (MOP), methamphetamine (MET) and ketamine (KET) were obtained on a single band. The detection limit (LOD) of this analytical method was 100-1000 times lower than that of colloidal gold test strips. The detection limits of MOP, MET and KET were 0.06 ng mL, 0.1 ng mL and 1.0 ng mL, respectively. No cross-reaction was observed when morphine, methamphetamine and ketamine were tested simultaneously with this method. And 184 hair samples were tested simultaneously, and the detected amount was very close to the results of LC-MS. The immunochromatographic strip showed good stability in repeated tests, and the coefficient of variation was less than 15%. Fluorescence immunochromatography strips and handheld strip readers have the characteristics of portability, speed, ease of operation and high sensitivity, and may become powerful tools for screening drug abuse in hair in forensic medicine.

Download full-text PDF

Source
http://dx.doi.org/10.1039/d3ay01280hDOI Listing

Publication Analysis

Top Keywords

immunochromatographic strip
8
morphine methamphetamine
8
methamphetamine ketamine
8
colloidal gold
8
test strip
8
tested simultaneously
8
strip
5
design development
4
development lanthanide-labeled
4
lanthanide-labeled immunochromatographic
4

Similar Publications