Article Abstract

Purpose: To identify how the inner retinal layer and microvasculature change with age by analyzing the relationships of ganglion cell-inner plexiform layer (GC-IPL) thickness, vessel density (VD), and the ratio of these measurements with age in healthy eyes.

Methods: Participants were divided into five groups according to age. The GC-IPL thickness, VD, and GC-IPL/VD ratio were compared among the groups. Linear regression analyses were performed to identify relationships of GC-IPL/VD ratio with age.

Results: The average GC-IPL thicknesses were 84.84 ± 5.28, 84.22 ± 5.30, 85.20 ± 6.29, 83.29 ± 7.06, and 82.26 ± 5.62 μm in the 20s, 30s, 40s, 50s, and 60s age groups, respectively. The VDs were 20.94 ± 1.50, 21.06 ± 1.50, 20.99 ± 1.03, 20.71 ± 0.93, and 19.74 ± 1.73 mm-1 in the 20s, 30s, 40s, 50s, and 60s age groups, respectively. The GC-IPL/VD ratio was 4.05, 4.00, 4.06, 4.02, and 4.17 in each group, respectively, and the ratio of the 60s age group was significantly higher than that of other groups. In linear regression analyses, the GC-IPL/VD ratio was significantly associated with age in the participants aged ≥ 50 years (B = 0.014, P = 0.013), whereas it was not in the participants aged < 50 years (B = 0.003, P = 0.434).

Conclusions: GC-IPL thickness and macular VD showed a tendency to decrease beginning in the 50s age group and the GC-IPL/VD ratio was significantly increased in the 60s age group. Additionally, the GC-IPL/VD ratio was positively associated with age in subjects aged ≥ 50 years, which implies a more pronounced decline over time in VD rather than GC-IPL thickness.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10584181PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0292942PLOS

Publication Analysis

Top Keywords

gc-ipl/vd ratio
24
gc-ipl thickness
16
60s age
16
age group
12
age
11
ganglion cell-inner
8
cell-inner plexiform
8
plexiform layer
8
thickness vessel
8
vessel density
8

Similar Publications

Purpose: To identify how the inner retinal layer and microvasculature change with age by analyzing the relationships of ganglion cell-inner plexiform layer (GC-IPL) thickness, vessel density (VD), and the ratio of these measurements with age in healthy eyes.

Methods: Participants were divided into five groups according to age. The GC-IPL thickness, VD, and GC-IPL/VD ratio were compared among the groups.

View Article and Find Full Text PDF

Superficial and deep macular vessel density (VD) is decreased in eyes with glaucoma. Superficial VD comprises both the retinal nerve fiber layer (RNFL) and ganglion cell/inner plexiform layer (GC/IPL), and various terms have been used previously to describe the layers of macular VD. In our study, we readjusted the macular segmentation.

View Article and Find Full Text PDF

The purpose of this study was to identify how chronic hypertension (HTN) and hypertensive retinopathy (HTNR) have different effects on retinal damage including inner retinal thinning and microvasculature impairment. The subjects were divided into three groups: controls, HTN patients without HTNR (HTN group), and patients with relieved HTNR (HTNR group). The ganglion cell-inner plexiform layer (GC-IPL) thickness, vessel density (VD), and GC-IPL/VD ratio were compared among the groups.

View Article and Find Full Text PDF

Purpose: To investigate retinal blood flow in patients with hypertension using optical coherence tomography angiography (OCTA) and the relationship between blood flow metrics and ganglion cell-inner plexiform layer (GC-IPL) thickness.

Design: Retrospective, cross-sectional study.

Methods: A total of 201 eyes from 117 healthy subjects and 84 hypertensive patients without any ocular abnormalities were included.

View Article and Find Full Text PDF