98%
921
2 minutes
20
A derivatization-free hydrophilic-interactive chromatography-mass spectrometry (HILIC-MS/MS) method was developed for quantifying low levels of alendronate in human plasma. Alendronate was separated and concentrated using calcium co-precipitation and analyzed by HILIC-MS/MS, requiring only a 300 μL plasma sample for each analysis. The method is simpler, safer, and more environmentally friendly than the conventional LC-MS/MS method that requires solid-phase extraction and derivatization steps during sample pretreatment. The method was validated for selectivity, linearity, precision, accuracy, extraction recovery, matrix effect and limit of quantification. The between-run precisions were no more than 7.1 % with accuracy ranging from - 1.7-6.3 %; extraction recovery was determined to be 85.3 %; while validation results indicated that the method was suitable for accurately quantifying alendronate concentrations in the range from 0.2 to 50 ng/mL. The approach was used successfully for high throughput analysis of alendronate in more than 3700 plasma samples from 120 subjects in a bioequivalence study.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jpba.2023.115775 | DOI Listing |
Nanoscale
September 2025
School of Materials Science and Engineering, Beihang University, Beijing 100191, China.
The challenge of photocatalytic hydrogen production has motivated a targeted search for MXenes as a promising class of materials for this transformation because of their high mobility and high light absorption. High-throughput screening has been widely used to discover new materials, but the relatively high cost limits the chemical space for searching MXenes. We developed a deep-learning-enabled high-throughput screening approach that identified 14 stable candidates with suitable band alignment for water splitting from 23 857 MXenes.
View Article and Find Full Text PDFRev Sci Instrum
September 2025
Department of Physics, University of Strathclyde, Glasgow, G1 1XJ, United Kingdom.
The calibration of the JET x-ray spectrometer is presented. The absolute throughput, diffractor focusing, and instrument function of the spectrometer are presented, and the quality of the ion temperature measurement is re-assessed, particularly at the lower end. The addition of a second diffractor enables the simultaneous measurements of the spectra from H- and He-like nickel, which widens the spatial coverage of the core-ion temperature measurements for high-performance plasmas at a fixed Bragg angle range.
View Article and Find Full Text PDFInt J Environ Health Res
September 2025
Department of Epidemiology, School of Public Health, Shanxi Medical University, Jinzhong, China.
The mechanism underlying the effects of Polycyclic aromatic hydrocarbons (PAHs) on missed abortion (MA) remains unclear. This study explored the relationship between PAHs exposure, telomere length (TL), metabolizing enzyme gene polymorphism, and MA in a case-control study with 253 pregnant women. A competitive enzyme-linked immunosorbent assay (ELISA) was used to quantify PAH-DNA adducts.
View Article and Find Full Text PDFBackground: Actinomyces graevenitzii is a relatively uncommon Actinomyces species, which is an oral species and predominantly recovered from respiratory locations [1,2]. It is a gram-positive anaerobic bacteria or microaerobic filamentation bacteria, which can induce pyogenic and granulomatous inflammation characterized by swelling and concomitant pus, sinus formation, and the formation of yellow sulfur granules. All tissues and organs can be infected; the most common type involves the neck and face (55%), followed by the abdominal and pelvic cavities (20%).
View Article and Find Full Text PDFJ Proteome Res
September 2025
State Key Laboratory of Medical Proteomics, Beijing Proteome Research Center, National Center for Protein Sciences (Beijing), Research Unit of Proteomics & Research and Development of New Drug of Chinese Academy of Medical Sciences, Institute of Lifeomics, Beijing 102206, China.
Hepatocellular carcinoma (HCC) constitutes approximately 90% of liver cancers, yet its early detection remains challenging due to the low sensitivity of current diagnostic methods and the difficulty in identifying minimal cancer cells within the body. This study employed a patient-derived xenograft (PDX) mouse model to screen for biomarkers, leveraging its advantage of low background interference compared to human serum exosome studies. Using a novel microextraction technique, exosomes were isolated from just one microliter of serum from HCC PDX mice, followed by proteomic profiling.
View Article and Find Full Text PDF