98%
921
2 minutes
20
Background High variability in prostate MRI quality might reduce accuracy in prostate cancer detection. Purpose To prospectively evaluate the quality of MRI scanners taking part in the quality control phase of the global PRIME (Prostate Imaging Using MRI ± Contrast Enhancement) trial using the Prostate Imaging Quality (PI-QUAL) standardized scoring system, give recommendations on how to improve the MRI protocols, and establish whether MRI quality could be improved by these recommendations. Materials and Methods In the prospective clinical trial (PRIME), for each scanner, centers performing prostate MRI submitted five consecutive studies and the MRI protocols (phase I). Submitted data were evaluated in consensus by two expert genitourinary radiologists using the PI-QUAL scoring system that evaluates MRI diagnostic quality using five points (1 and 2 = nondiagnostic; 3 = sufficient; 4 = adequate, 5 = optimal) between September 2021 and August 2022. Feedback was provided for scanners not achieving a PI-QUAL 5 score, and centers were invited to resubmit new imaging data using the modified protocol (phase II). Descriptive comparison of outcomes was made between the MRI scanners, feedback provided, and overall PI-QUAL scores. Results In phase I, 41 centers from 18 countries submitted a total of 355 multiparametric MRI studies from 71 scanners, with nine (13%) scanners achieving a PI-QUAL score of 3, 39 (55%) achieving a score of 4, and 23 (32%) achieving a score of 5. Of the 48 ( = 71 [68%]) scanners that received feedback to improve, the dynamic contrast-enhanced sequences were those that least adhered to the Prostate Imaging Reporting and Data System, version 2.1, criteria (44 of 48 [92%]), followed by diffusion-weighted imaging (20 of 48 [42%]) and T2-weighted imaging (19 of 48 [40%]). In phase II, 36 centers from 17 countries resubmitted revised studies, resulting in a total of 62 ( = 64 [97%]) scanners with a final PI-QUAL score of 5. Conclusion Substantial variation in global prostate MRI acquisition parameters as a measure of quality was observed, particularly with DCE sequences. Basic evaluation and modifications to MRI protocols using PI-QUAL can lead to substantial improvements in quality. Clinical trial registration no. NCT04571840 Published under a CC BY 4.0 license. See also the editorial by Almansour and Chernyak in this issue.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1148/radiol.231130 | DOI Listing |
Stroke
September 2025
Department of Neurology, Vagelos College of Physicians and Surgeons, Columbia University, New York. (F.C.P., M.R., M.S., A.K., S.G., S.A., S.P., J.C., D.J.R.).
Background: Major ABO-incompatible platelet transfusions are associated with poor intracerebral hemorrhage (ICH) outcomes, yet drivers for this relationship remain unclear. Brain magnetic resonance imaging (MRI) ischemic lesions after ICH are neuroimaging biomarkers of secondary brain injury and are associated with poor outcomes. Given that ABO-incompatible platelet transfusions can induce immune complex formation, thrombo-inflammation, and endothelial barrier disruption, factors that could exacerbate cerebral ischemia, we explored whether major ABO-incompatible platelet transfusions are risk factors for ischemic lesions on brain MRI after ICH.
View Article and Find Full Text PDFHypertension
September 2025
Division of Cardiovascular Medicine, Hospital of the University of Pennsylvania, Philadelphia (C.B., H.T., J.A.C.).
Background: Aortic structural degeneration occurs with aging; however, 3-dimensional geometric remodeling has not been well characterized in large populations.
Methods: We segmented the thoracic aorta from magnetic resonance images of 56 164 UKB (UK Biobank) participants and computed tomography images of 9417 PMBB (Penn Medicine Biobank) participants. We quantified structural measurements of elongation, dilation, tortuosity, and curvature across the thoracic aorta.
Diagn Interv Radiol
September 2025
Department of Internal Medicine, Biomedical Research Institute, Pusan National University Hospital, Pusan National University School of Medicine, Busan, Korea.
Purpose: To evaluate the feasibility of abbreviated liver magnetic resonance imaging (AMRI) with a second-shot arterial phase (SSAP) image for the viability of treated hepatocellular carcinoma (HCC) after non-radiation locoregional therapy (LRT).
Methods: We retrospectively enrolled patients with non-radiation LRT for HCC who underwent the modified gadoxetic acid-enhanced liver MRI protocol, which includes routine dynamic and SSAP imaging after the first and second injection of gadoxetic acid, respectively (6 mL and 4 mL, respectively), and an available reference standard for tumor viability in the treated HCC between March 2021 and February 2022. Two radiologists independently reviewed the full-protocol MRI (FP-MRI) and AMRI with SSAP.
Br J Psychiatry
September 2025
Neuroscience Research Australia, Randwick, New South Wales, Australia.
Background: Individuals with a family history of bipolar disorder are at increased risk of developing affective psychopathology. Longitudinal imaging studies in young people with familial risk have been limited, and cortical developmental trajectories in the progression towards illness remain obscure.
Aims: To establish high-resolution longitudinal differences in cortical structure that are associated with risk of bipolar disorder.
Hum Brain Mapp
September 2025
Department of Neurosurgery, Heidelberg University Hospital, Heidelberg, Germany.
Postoperative aphasia (POA) is a common complication in patients undergoing surgery for language-eloquent lesions. This study aimed to enhance the prediction of POA by leveraging preoperative navigated transcranial magnetic stimulation (nTMS) language mapping and diffusion tensor imaging (DTI)-based tractography, incorporating deep learning (DL) algorithms. One hundred patients with left-hemispheric lesions were retrospectively enrolled (43 developed postoperative aphasia, as the POA group; 57 did not, as the non-aphasia (NA) group).
View Article and Find Full Text PDF