Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Efficient tuning of the polarity of photoactive nanomaterials is of great importance in improving the performance of photoelectrochemical (PEC) sensing platforms. Herein, polarity of the AgS/AgInS heterojunction is converted by radical-induced positive feedback polydopamine (PDA) adhesion, which is further employed to develop a signal-switchable PEC biosensor. In the nanocomposites, AgS and AgInS achieve electron-hole separation, exhibiting a strong anodic PEC response. Under the irradiation of light, the AgS/AgInS heterojunction is able to produce superoxide radical and hydroxyl radical intermediate species, leading to the polymerization of dopamine (DA) and the subsequent adhesion of PDA onto the AgS/AgInS heterojunction (AgS/AgInS@PDA). By constructing a new electron-transfer pathway with PDA, the polarity of the AgS/AgInS heterojunction is converted, and the PEC response changes from anodic to cathodic photocurrents. In addition, since the photoreduction activity of PDA is stronger than that of the AgS/AgInS heterojunction, more superoxide radical can be produced by AgS/AgInS@PDA once PDA is generated, thereby promoting the generation of PDA. Consequently, a positive feedback mechanism is established to enhance the polarity conversion of the AgS/AgInS heterojunction and amplify the responding to DA. As a result, the bioanalytical method is capable of sensitively quantifying DA in 10 orders of magnitude with an ultralow limit of detection. Moreover, the applicability of this biosensor in real samples is identified by measuring DA in fetal bovine serum and compared with a commercial ELISA method. Overall, this work offers an alternative perspective for adjusting photogenerated carriers of nanomaterials and designing high-performance PEC biosensors.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/acs.analchem.3c02758 | DOI Listing |