Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

To determine the effects of intense training on aortic pulse wave variables and hemodynamic parameters at baseline and at recovery from maximal exercise testing (MaxET) in triathletes compared with sedentary individuals. In this prospective and experimental study, 21 triathletes and 21 sedentary individuals were recruited and evaluated prior and two minutes after the MaxET using the Mobil-O-Graph®, which estimates the aortic pulse wave from the brachial artery pressure. The augmentation index (AIx@75) was lower in triathletes after the MaxET compared to control group (16.34 ± 5.95 vs. 23.5 ± 8.53%, p = 0.001), while the pulse wave velocity (PWV) was similar between groups. The heart rate was significantly lower at baseline and after MaxET in triathletes group (55.70 ± 8.95 bpm 91.49 ± 11.39 bpm) compared with control group (62.11 ± 6.70 bpm; 102.08 ± 10.85 bpm). The stroke volume was significantly higher at baseline (96.08 ± 13.96 ml; 86.17 ± 11.24 ml) and after MaxET in triathletes group (69.15 ± 6.51 ml, 58.38 ± 6.99 ml) compared with control group. Triathetes show lower value of AIx@75 after MaxET in comparison with the control group. AIx@75, in addition to being an indirect measure of arterial stiffness, is also a measure of left ventricular afterload. Thus, the lower AIx@75 in triathletes may be due to their lower left ventricular afterload, lower myocardial oxygen demand, and greater coronary perfusion than sedentary individuals. The hemodynamic changes observed in triathletes at rest and during an acute exercise bout are distinctive characteristics of aerobic physical training.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10517919PMC
http://dx.doi.org/10.1038/s41598-023-43303-7DOI Listing

Publication Analysis

Top Keywords

pulse wave
16
control group
16
aortic pulse
12
maxet triathletes
12
sedentary individuals
12
compared control
12
triathletes
8
triathletes group
8
lower aix@75
8
left ventricular
8

Similar Publications

Bismuth ferrite (BiFeO) is a semiconductor with multiferroic properties, synthesized by the sol-gel method. While static high-pressure studies have advanced our understanding of the phase behavior of BiFeO, the effects of dynamic pressure acoustic shock waves remain unexplored. In this study, BiFeO was subjected to 100 shock pulses with 0.

View Article and Find Full Text PDF

Cardiovascular assessments in children and adolescents with hypertension are essential for detecting early signs of organ damage and guiding timely interventions. The pathophysiology of pediatric hypertension involves a complex interplay of arterial stiffness, endothelial dysfunction, metabolic disturbances, activation of the renin-angiotensin-aldosterone system, and immune dysregulation. These mechanisms collectively contribute to target organ damage, particularly in the cardiovascular system.

View Article and Find Full Text PDF

Background: Remimazolam tosilate, a novel ultra-short-acting benzodiazepine, demonstrates promising safety profiles in clinical settings. While both remimazolam tosilate and etomidate provide hemodynamic stability during anesthesia induction, limited research has directly compared their effects on electroencephalogram (EEG) burst suppression (periods of transient brain wave silence), a potential predictor of adverse neurological outcomes. This study aims to compare the incidence rate of EEG burst suppression (ESR) with remimazolam tosilate versus etomidate by reviewing the drug regimens used by different anesthesiologists in clinical practice.

View Article and Find Full Text PDF

Introduction: Wave speed (WS) mapping, enabled by omnipolar technology, allows for real-time visualization of local conduction velocity (CV). Its utility in ventricular tachycardia (VT) ablation has not been fully characterized.

Methods And Results: We describe a case series of patients undergoing VT ablation in which WS mapping was applied alongside established techniques such as peak frequency (PF) mapping and isochronal late activation mapping (ILAM).

View Article and Find Full Text PDF

Pulse diagnosis holds a pivotal role in traditional Chinese medicine (TCM) diagnostics, with pulse characteristics serving as one of the critical bases for its assessment. Accurate classification of these pulse pattern is paramount for the objectification of TCM. This study proposes an enhanced SMOTE approach to achieve data augmentation, followed by multi-domain feature extraction.

View Article and Find Full Text PDF