Objectives: The aim of this study was to evaluate the relationship between atrioventricular valve and ventricular function in Fontan survivors, including the effect of atrioventricular valve surgery.
Methods: Analysis focused on transplant-free survival and the need for atrioventricular valve surgery in single ventricle patients after Fontan completion. Longitudinal echocardiographic examination of long-term valve and ventricular function was performed.
Results: Fontan completion was performed in 113 patients, having a right univentricular morphology in 33.6%, a left ventricle morphology in 62.8% and ambiguous in 3.6%. Perioperative mortality was 2.7% (n = 3). Within a median follow-up of 16.3 years (interquartile range 10.6-23.6), transplant-free survival was 96.1 ± 1.9% and 90.4 ± 5.8% at 10-25 years. Twenty AV valve procedures were performed in 14 (12.4%) children, respectively, pre-Fontan (n = 10), per-Fontan (n = 8) and post-Fontan (n = 2), resulting in a cumulative incidence of AV valve surgery is 5.7 ± 2.2% and 12.3 ± 3.2% at 1-5 years. Atrio-ventricular valve function deteriorated over time [hazard ratio (HR) 1.112, 95% confidence interval (CI) 1.089-1.138, P < 0.001], without difference for valve morphology (P = 0.736) or ventricular dominance (P = 0.484). AV valve dysfunction was greater in patients requiring AV valve surgery (HR 20.383, 95% CI 6.223-36.762, P < 0.001) but showed a comparable evolution since repair to those without valve surgery (HR 1.070, 95% CI 0.987-1.160, P = 0.099). Progressive time-related ventricular dysfunction was observed (HR 1.141, 95% CI 1.097-1.182, P < 0.001), significantly less in left ventricle-dominance (HR 0.927, 95% CI 0.860-0.999, P = 0.047) but more after AV valve surgery (HR 1.103, 95% CI 1.014-1.167, P = 0.022).
Conclusions: In a homogeneously treated Fontan population, 25-year transplant-free survival is encouraging. Atrio-ventricular valve surgery was necessary in 12.4%, resulting mostly in a durable valve function. However, a slow time-related decline of atrioventricular valve function as of ventricular function is worrisome, evoking a role for additional heart failure therapy.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/ejcts/ezad305 | DOI Listing |
Rev Cardiovasc Med
August 2025
Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel - Vrije Universiteit Brussel, European Reference Networks Guard-Heart, 1090 Brussels, Belgium.
Despite continued advancements in transcatheter aortic valve implantation (TAVI) techniques, the incidence of permanent pacemaker implantation (PPI) remains substantial. Established predictors of PPI include advanced age, pre-existing electrocardiographic conduction abnormalities, prosthetic valve type, implantation depth, and anatomical parameters, such as membranous septum length, which are currently under active investigation. In routine clinical practice, the management strategy often involves the temporary placement of a transvenous pacemaker lead, followed by a period of observation.
View Article and Find Full Text PDFJTCVS Open
August 2025
Division of Cardiothoracic Surgery, Department of Surgery, University of Southern California, Los Angeles, Calif.
Objective: Patients with heterotaxy-associated congenital heart disease often require multiple operations, which may have a cumulative effect on their outcomes. This study aimed to define the cardiac surgical course in a large cohort and identify longitudinal risk factors for death/transplant.
Methods: All patients with heterotaxy-associated congenital heart disease who underwent cardiac surgery at one institution from 2005 to 2022 were retrospectively reviewed.
Struct Heart
September 2025
The Carl and Edyth Lindner Research Center at the Christ Hospital, Cincinnati, Ohio, USA.
Severe, untreated tricuspid regurgitation is associated with worse clinical outcomes. While isolated tricuspid valve (TV) surgery has been linked to poor long-term outcomes, transcatheter TV therapies, including edge-to-edge repair and transcatheter tricuspid valve replacement (TTVR), have emerged as effective alternatives and have been shown to improve outcomes, leading to their regulatory approval in the United States. Conduction system abnormalities are commonly seen among patients undergoing TTVR due to the close proximity of the atrioventricular node and the His bundle to the TV annulus.
View Article and Find Full Text PDFHeart Rhythm O2
August 2025
Department of Cardiology, Rouen University Hospital, UNIROUEN, INSERM U1096, Rouen, France.
Background: A high burden of right ventricular pacing (RVP) increases the risk of hospitalization because of heart failure. Data on predictive factors for high burden of RVP in patients with permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR) are limited.
Objective: This study aimed to identify predictors of high RVP burden in patients with current indications for PPI after TAVR.
J Thorac Cardiovasc Surg
September 2025
Division of Congenital Heart Surgery, Texas Children's Hospital, Houston, Tex; Department of Surgery, Baylor College of Medicine, Houston, Tex.