A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Distance-Regulated Photoelectrochemical Sensor "Signal-On" and "Signal-Off" Transitions for the Multiplexed Detection of Viruses Exposed in the Aquatic Environment. | LitMetric

Distance-Regulated Photoelectrochemical Sensor "Signal-On" and "Signal-Off" Transitions for the Multiplexed Detection of Viruses Exposed in the Aquatic Environment.

Anal Chem

Hubei Key Laboratory of Pollutant Analysis & Reuse Technology, College of Chemistry and Chemical Engineering, Hubei Normal University, Huangshi 435002, P. R. China.

Published: September 2023


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Photochemical (PEC) sensors were severely limited for multiplex detection applications due to the cross interference between multiplex signals at the single recognition interface. In this work, a distance-regulated PEC sensor was developed for multiplex detection by using an i-Motif sequence with conformational transformation activity as the signal transduction unit. Through dynamic regulation of the spatial distance between the end site of the functional sequence and the electrode material, the photogenerated electrons on the surface of the sensor were directionally transferred. Thus, a PEC sensor with "signal-on" and "signal-off" dual signal output modes was developed for simultaneous detection of multitarget molecules. Combining isothermal nucleic acid amplification, the PEC sensor constructed in this work was successfully applied to the detection of two virus ( and ) nucleic acid sequences. Under the optimal condition, this bioassay protocol exhibits a linear range of 0.01-100 nM for both viruses with detection limits of 0.72 and 0.53 pM, respectively. In this study, a stimulus-mediated distance regulation strategy successfully addressed the transduction of multiplex detection signals at the single recognition interface of the PEC sensor. It is expected that the technical barriers to multiplex detection of PEC sensors will be overcome and the application of PEC sensing technology will be expanded in the field of environmental analysis.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.analchem.3c02316DOI Listing

Publication Analysis

Top Keywords

multiplex detection
16
pec sensor
16
sensor "signal-on"
8
"signal-on" "signal-off"
8
detection
8
pec sensors
8
signals single
8
single recognition
8
recognition interface
8
nucleic acid
8

Similar Publications