Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Atrial fibrillation (AF) and heart failure with preserved ejection fraction (HFpEF) are frequent co-morbid conditions. In patients with symptomatic AF and preserved left ventricular ejection fraction the clinical diagnosis of HFpEF may be difficult, as history, examination, and echocardiography are not sensitive or specific. This study sought to assess the prevalence of HFpEF in patients undergoing AF ablation utilizing resting and post-tachycardia pacing left atrial pressure (LAP) measurements. This retrospective cohort study consisted of consecutive patients with symptomatic AF and preserved left ventricular ejection fraction who had invasive hemodynamic assessment (IHA) of LAP under resting and post-tachycardia pacing conditions while undergoing AF ablation from 2020 to 2022 at a tertiary care academic medical center. Elevated LAP was defined as ≥15 mm Hg at rest and ≥15 mm Hg post-tachycardia pacing. Patients were stratified into 3 groups: (1) normal resting and post-tachycardia pacing LAP (control group), (2) elevated resting LAP (apparent HFpEF), (3) normal resting but elevated post-tachycardia pacing LAP (occult HFpEF). A total of 78 patients were included with age 64.6 ± 9.1 years, 28 (36%) female, body mass index 33.3 ± 6.5 kg/m, 5 (6%) paroxysmal and 73 (94%) persistent AF, and CHADS-VASc 3.0 ± 1.5. IHA categorized 31 (40%), 32 (41%), and 15 patients (19%) into groups 1, 2, and 3 respectively. Notably, while only 9 patients (12%) were diagnosed with HFpEF based on clinical evaluation, 47 patients (60%) were diagnosed by IHA. IHA in patients undergoing AF ablation suggests a high prevalence of clinically undiagnosed HFpEF through a novel methodology measuring resting and post-tachycardia pacing LAP.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.amjcard.2023.07.179DOI Listing

Publication Analysis

Top Keywords

post-tachycardia pacing
28
resting post-tachycardia
20
ejection fraction
16
patients undergoing
12
undergoing ablation
12
pacing lap
12
patients
10
heart failure
8
failure preserved
8
preserved ejection
8

Similar Publications

Atrial fibrillation (AF) and heart failure with preserved ejection fraction (HFpEF) are frequent co-morbid conditions. In patients with symptomatic AF and preserved left ventricular ejection fraction the clinical diagnosis of HFpEF may be difficult, as history, examination, and echocardiography are not sensitive or specific. This study sought to assess the prevalence of HFpEF in patients undergoing AF ablation utilizing resting and post-tachycardia pacing left atrial pressure (LAP) measurements.

View Article and Find Full Text PDF

Background: In patients with sinoatrial nodal (SAN) dysfunction, atrial pauses lasting several seconds may follow rapid atrial pacing or paroxysmal tachycardia (tachy-brady arrhythmias). Clinical studies suggest that adenosine may play an important role in SAN dysfunction, but the mechanism remains unclear.

Objective: To define the mechanism of SAN dysfunction induced by the combination of adenosine and tachycardia.

View Article and Find Full Text PDF

A 74-year-old male presented to our emergency room with history of sudden onset palpitations associated with syncope. He had a single-chamber implantable cardioverter defibrillator implanted for secondary prevention of sudden cardiac death due to ischaemic cardiomyopathy. Interrogation of the device revealed episodes of non-sustained ventricular tachycardia (NSVT) at 220 ms.

View Article and Find Full Text PDF

Background And Purpose: The effects of angiotensin-converting enzyme inhibitor on long-term atrial electrophysiologic and structural remodeling are still unclear. The purpose of this study is to investigate the effects of Cilazapril on atrial electrical, structural, and functional remodeling in atrial fibrillation (AF) dogs induced by chronic rapid atrial pacing.

Methods: Twenty dogs were randomly divided into sham-operated group (n = 6), control group (n = 7), and Cilazapril group (n = 7).

View Article and Find Full Text PDF

Poor baroreflex gain is a marker of heightened sympathetic activity post-tachycardia termination in humans.

Clin Auton Res

December 2003

Division of Cardiology, Dept. of Internal Medicine, University of Texas, Southwestern Medical Center, Room C57.102, 5323 Harry Hines Blvd, Dallas, TX 75390-9047, USA.

We hypothesized that sympathetic nerve activity (SNA) remains elevated after tachycardia termination in patients with low baroreflex gain (BRG), and decreased to or below baseline in patients with high BRG. In a cohort of patients who participated in a previously published study [3], BRG, SNA, blood pressure, and central venous pressure were measured immediately after the termination of simulated tachycardia. While the hemodynamic responses following tachycardia termination were similar in both groups, SNA remained elevated in patients with low BRG compared to a decrease below baseline levels in patients with high BRG (p = 0.

View Article and Find Full Text PDF