A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Ventricular fibrillation waveform properties influenced by thoracic impedance guided chest compressions in a porcine model. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background And Objective: Quantitative measures extracted from ventricular fibrillation (VF) waveform reflect the metabolic state of the myocardium and are associated with survival outcome. The quality of delivered chest compressions during cardiopulmonary resuscitation are also linked with survival. The aim of this research is to explore the viability and effectiveness of a thoracic impedance (TI) based chest compression (CC) guidance system to control CC depth within individual subjects and influence VF waveform properties.

Methods: This porcine investigation includes an analysis of two protocols. CC were delivered in 2 min episodes at a constant rate of 110 CC min. Subject-specific CC depth was controlled using a TI-thresholding system where CC were performed according to the amplitude (Z 0.125 to 1.250 Ω) of a band-passed TI signal (Z). Protocol A was a retrospective analysis of a 12-porcine study to characterise the response of two VF waveform metrics: amplitude spectrum area (AMSA) and mean slope (MS), to varying CC quality. Protocol B was a prospective 12-porcine study to determine if changes in VF waveform metrics, due to CC quality, were associated with defibrillation outcome.

Results: Protocol A: A directly proportional relationship was observed between Z and CC depth applied within each subject (r = 0.90; p <0.001). A positive relationship was observed between Z and both AMSA (p <0.001) and MS (p <0.001), where greater TI thresholds were associated with greater waveform metrics.

Protocol B: MS was associated with return of circulation following defibrillation (odds ratio = 2.657; p = 0.043).

Conclusion: TI-thresholding was an effective way to control CC depth within-subjects. Compressions applied according to higher TI thresholds evoked an increase in AMSA and MS. The response in MS due to deeper CC resulted in a greater incidence of ROSC compared to shallow chest compressions.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cmpb.2023.107780DOI Listing

Publication Analysis

Top Keywords

ventricular fibrillation
8
fibrillation waveform
8
thoracic impedance
8
chest compressions
8
12-porcine study
8
waveform metrics
8
waveform
5
waveform properties
4
properties influenced
4
influenced thoracic
4

Similar Publications