A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Validation of analytical HPLC with post-column injection as a method for rapid and precise quantification of radiochemical yields. | LitMetric

Validation of analytical HPLC with post-column injection as a method for rapid and precise quantification of radiochemical yields.

J Chromatogr B Analyt Technol Biomed Life Sci

Forschungszentrum Jülich GmbH, Institute of Neurosciences and Medicine, Nuclear Chemistry (INM-5), Wilhelm-Johnen-Str., 52428 Jülich, Germany; Institute of Radiochemistry and Experimental Molecular Imaging, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpener Str. 6

Published: August 2023


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Accurate assessment of isolated radiochemical yields (RCYs) is a prerequisite for efficient and reliable optimization of labeling reactions. In practice, radiochemical conversions (RCCs) determined by HPLC analysis of crude reaction mixtures are often used to estimate RCYs. However, incomplete recovery of radioactivity from the stationary phase can lead to significant inaccuracies if RCCs are calculated based on the activity eluted from the column (i.e. the summed integrals of all peaks). Here, we validate a simple and practical method that overcomes problems associated with retention of activity on the column by determination of the total activity in the sample using post-column injection. Post-column injections were carried out using an additional injection valve, which was placed between the outlet of the HPLC column and the inlet of the detectors. 2-[F]Fluoropyridine ([F]FPy) and 8-cyclopentyl-3-(3-[F]fluoropropyl)-1-propylxanthine ([F]CPFPX) were prepared with radiochemical purities of > 99.8% and mixed with [F]fluoride at a ratio of 1:1 to simulate reaction mixtures obtained by radiolabeling reactions with an RCC of 50%. The samples were analyzed on three different C HPLC columns using neutral and acidic mobile phases. RCCs determined using the summed area of all peaks in the chromatograms were compared with those determined using post-column injection. Additionally, RCCs determined by post-column injection were corrected for activity losses before, during and after radiosyntheses to afford analytical RCYs, which were compared with isolated RCYs. Determination of RCCs based on the summed area of all peaks gave correct results under certain chromatographic conditions, but led to overestimation of the actual RCCs by up to 50% in other cases. In contrast, determination of RCCs using post-column injection provided precise results in all cases, and often significantly reduced analysis time. Moreover, analytical RCYs calculated from RCCs determined by post-column injection showed excellent agreement with isolated RCYs (<3% deviation). In conclusion, HPLC analysis using post-column injection enables reliable determination of RCCs independent of the chromatographic conditions and, together with a simple activity balance, rapid and accurate prediction of isolated RCYs.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jchromb.2023.123847DOI Listing

Publication Analysis

Top Keywords

post-column injection
24
rccs determined
16
determined post-column
12
radiochemical yields
8
rccs
8
reaction mixtures
8
summed area
8
area peaks
8
analytical rcys
8
isolated rcys
8

Similar Publications