Objective: This study aimed to evaluate the effects on the dislocation and misalignment of the cuffed end of a double-lumen endobronchial tube (DLT) when a patient moves from a horizontal to a lateral position without fixation.
Methods: A total of 148 patients who had undergone video-assisted thoracoscope surgery were enrolled and randomly divided into two groups: a group in which the periportal end of the DLT was fixed with tape (group I; = 74) and a group in which the periportal end of the DLT remained unfixed (group II; = 74). Both groups were given an intravenous induction for double-lumen endobronchial intubation and then moved from a horizontal position to a lateral position, after which the alignment of the bronchial cuffed end of the DLT was assessed using a fiberoptic bronchoscope.
Results: After lateral position, the dislocation rate of group I and group II was 44.6% and 20.2%, and the misalignment rate was 27.0% and 8.1%, respectively, the incidence of dislocation and misalignment was significantly lower in group II than in group I after the change to a lateral position ( < 0.05). After lateral position, the total rate of airway injury was 25.7% in group I and 5.4% in group II, the incidence of airway injury was significantly lower in group II than in group I ( < 0.05), as was the incidence of sore throat, hoarseness, and cough on postoperative day 1 ( < 0.05). The average outward dislocation of the periportal end of the DLT in group II was 1.5 cm.
Conclusion: A DLT without periportal fixation is less likely to be displaced and poorly aligned when the patient moves from a horizontal to a lateral position, which could facilitate intra-operative management and reduce the incidence of postoperative complications.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10453979 | PMC |
http://dx.doi.org/10.1080/07853890.2023.2247422 | DOI Listing |
Med Eng Phys
October 2025
Department of Engineering Science, University of Oxford, United Kingdom. Electronic address:
Traditionally, clinical devices are designed, tested and improved through lengthy and expensive laboratory experiments and clinical trials [1]. More recently, computational methods have allowed for rapid testing, speeding up the design process and enabling far more complete searches of design space. While computational models cannot fully capture the complexities of biological systems, they provide valuable insights into crucial underlying mechanisms, such as the effects of fluid-structure interactions (FSIs).
View Article and Find Full Text PDFOphthalmic Plast Reconstr Surg
September 2025
Department of Oculoplastic, Orbital & Lacrimal Surgery, Aichi Medical University Hospital. Nagakute, Aichi, Japan.
Purpose: To examine the position of the lower marginal arterial arcade (LMA) along the lower tarsal plate in microscopic specimens, particularly its relationship to anatomical landmarks.
Methods: Central sagittal sections of 27 lower eyelids (12 right, 10 left) from 15 Japanese cadavers (8 males, 7 females; aged 38-88 years, mean 70.5 years) were histologically examined.
Int J Surg Case Rep
September 2025
Pediatric Ophthalmology and Strabismus Division, King Khalid Eye Specialist Hospital, Riyadh, Saudi Arabia.
Introduction And Clinical Importance: To present a case of traumatic third cranial nerve palsy and discuss the management challenges associated with this condition.
Case Presentation: A 27-year-old male patient was referred to our hospital following a road traffic accident that resulted in multiple injuries, including traumatic brain injury, orbital injury. The patient presented with left complete upper lid ptosis, a fixed dilated pupil, and restricted extraocular muscle movements in the left eye except abduction with large exotropia >90 PD and hypotropia 25 PD diagnosed as left oculomotor nerve palsy.
Nat Sci Sleep
September 2025
Department of Otolaryngology Head and Neck Surgery, Beijing Tongren Hospital, Capital Medical University, Beijing, People's Republic of China.
Aim: Obstructive sleep apnea (OSA) is characterized by repetitive upper airway collapse during sleep, resulting in frequent cortical arousals. However, currently used frequency-based arousal metrics do not sufficiently capture the heterogeneity and clinical significance of arousal responses. The odds ratio product (ORP) is a novel electroencephalographic marker that provides a continuous assessment of sleep depth and has the potential to serve as an objective measure of arousal intensity.
View Article and Find Full Text PDFJB JS Open Access
September 2025
Division of Orthopedic Surgery, Department of Regenerative and Transplant Medicine, Niigata University Graduate School of Medical and Dental Science, Niigata, Japan.
Background: Lower extremity alignment in knee osteoarthritis (OA) is conventionally assessed using standing radiographs. However, symptoms often manifest during gait. Understanding dynamic alignment during gait may help characterize disease progression and inform treatment strategies.
View Article and Find Full Text PDF