Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Many reports describe using a supramaximal verification phase-exercising at a power output higher than the highest power output recorded during an incremental cardiopulmonary test-to validate VO. The impact of verification phases on estimating the proportion of individuals who increased VO in response to high-intensity interval training (HIIT) remains an underexplored area in the individual response literature. This analysis investigated the influence of same-day and separate-day verification phases during repeated measurements (incremental tests-INCR1 and INCR2; incremental tests + supramaximal verification phases-INCR1+ and INCR2+) of VO on typical error (TE) and the proportion of individuals classified as responders (i.e., the response rate) following 4 weeks of HIIT ( = 25) or a no-exercise control period ( = 9). Incorporation of supramaximal verification consistently reduced the standard deviation of individual response, TE, and confidence interval (CI) widths. However, variances were statistically similar across all groups ( > 0.05). Response rates increased when incorporating either one (INCR1 to INCR1+; 24%-48%, = 0.07) or two (INCR2 to INCR2+; 28%-48%, = 0.063) supramaximal verification phases. However, response rates remained unchanged when either zero-based thresholds or smallest worthwhile difference response thresholds were used (50% and 90% CIs, all > 0.05). Supramaximal verification phases reduced random variability in VO response to HIIT. Compared with separate-day testing (INCR2 and INCR2+), the incorporation of a same-day verification (INCR1+) reduced CI widths the most. Researchers should consider using a same-day verification phase to reduce uncertainty and better estimate VO response rate to HIIT.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1139/apnm-2023-0137 | DOI Listing |