Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The coronavirus disease (COVID-19) pandemic has emphasized the paucity of non-contact and non-invasive methods for the objective evaluation of dry eye disease (DED). However, robust evidence to support the implementation of mHealth- and app-based biometrics for clinical use is lacking. This study aimed to evaluate the reliability and validity of app-based maximum blink interval (MBI) measurements using DryEyeRhythm and equivalent traditional techniques in providing an accessible and convenient diagnosis. In this single-center, prospective, cross-sectional, observational study, 83 participants, including 57 with DED, had measurements recorded including slit-lamp-based, app-based, and visually confirmed MBI. Internal consistency and reliability were assessed using Cronbach's alpha and intraclass correlation coefficients. Discriminant and concurrent validity were assessed by comparing the MBIs from the DED and non-DED groups and Pearson's tests for each platform pair. Bland-Altman analysis was performed to assess the agreement between platforms. App-based MBI showed good Cronbach's alpha coefficient, intraclass correlation coefficient, and Pearson correlation coefficient values, compared with visually confirmed MBI. The DED group had significantly shorter app-based MBIs, compared with the non-DED group. Bland-Altman analysis revealed minimal biases between the app-based and visually confirmed MBIs. Our findings indicate that DryEyeRhythm is a reliable and valid tool that can be used for non-invasive and non-contact collection of MBI measurements, which can assist in accessible DED detection and management.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10442434PMC
http://dx.doi.org/10.1038/s41598-023-40968-yDOI Listing

Publication Analysis

Top Keywords

visually confirmed
12
maximum blink
8
blink interval
8
dry eye
8
eye disease
8
mbi measurements
8
app-based visually
8
confirmed mbi
8
cronbach's alpha
8
intraclass correlation
8

Similar Publications

Viscosity-sensitive fluorescent probes based on the hemicyanine for the organelle-specific visualization during autophagy and ferroptosis.

Spectrochim Acta A Mol Biomol Spectrosc

September 2025

College of Chemistry, Chemical Engineering and Material Science, Soochow University, No. 199 Ren'Ai Road, Suzhou 215123, China; Jiangsu Key Laboratory of Medical Optics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Science, Suzhou 215163, China. Electronic address: g

The dynamic monitoring of cell death processes remains a significant challenge due to the scarcity of highly sensitive molecular tools. In this study, two hemicyanine-based probes (5a-5b) with D-π-A structures were developed for organelle-specific viscosity monitoring. Both probes exhibited correlation with the Förster-Hoffmann viscosity-dependent relationship (R > 0.

View Article and Find Full Text PDF

Purpose: To describe the clinical and multimodal imaging features of a novel form of macular neovascularization (MNV), designated Type 4 MNV, defined by mixed Type 1 and Type 2 neovascularization (NV), extensive intraretinal anastomotic NV, and central posterior hyaloid fibrosis (CPHF).

Methods: This multicenter retrospective observational case series included patients with neovascular age-related macular degeneration (AMD) exhibiting both Type 1 and 2 MNV and an overlying anastomotic intraretinal NV network. This was confirmed with OCT and OCT angiography (OCTA).

View Article and Find Full Text PDF

Brain Activity During Electrical Stimulation of Visual-Motor Illusion with Enhanced Joint Motion Intensity.

J Mot Behav

September 2025

Department Department of Physical Therapy, Faculty of Human Health Sciences, Tokyo Metropolitan University, Tokyo, Japan.

Visual-motor illusion (VMI) is a kinesthetic illusion produced by viewing an image showing joint motion. VMI with enhanced joint movement intensity (power-VMI; P-VMI) is expected to activate a wide range of motor association brain regions, and when combined with electrical stimulation that activates the motor sensory cortex, further activation of brain activity can be expected. This study aimed to verify the effectiveness of VMI using functional near-infrared spectroscopy to confirm brain activity during combined P-VMI and electrical stimulation.

View Article and Find Full Text PDF

Fiber-optic bronchoscopy (FOB) plays a crucial role in the diagnosis and management of various pulmonary diseases by offering direct visualization of the airways and enabling targeted sampling for microbiological and histopathological evaluation. This study aimed to assess the clinical, radiological, microbiological, and histopathological profiles of patients undergoing FOB. A retrospective analysis of 103 participants who underwent the procedure over one year was conducted.

View Article and Find Full Text PDF

Introduction: Accurate identification of cherry maturity and precise detection of harvestable cherry contours are essential for the development of cherry-picking robots. However, occlusion, lighting variation, and blurriness in natural orchard environments present significant challenges for real-time semantic segmentation.

Methods: To address these issues, we propose a machine vision approach based on the PIDNet real-time semantic segmentation framework.

View Article and Find Full Text PDF