A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Myocardial infarction detection using ITD, DWT and deterministic learning based on ECG signals. | LitMetric

Myocardial infarction detection using ITD, DWT and deterministic learning based on ECG signals.

Cogn Neurodyn

Department of Mechanical, Industrial and Systems Engineering, University of Rhode Island, Kingston, RI 02881 USA.

Published: August 2023


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Nowadays, cardiovascular diseases (CVD) is one of the prime causes of human mortality, which has received tremendous and elaborative research interests regarding the prevention issue. Myocardial ischemia is a kind of CVD which will lead to myocardial infarction (MI). The diagnostic criterion of MI is supplemented with clinical judgement and several electrocardiographic (ECG) or vectorcardiographic (VCG) programs. However the visual inspection of ECG or VCG signals by cardiologists is tedious, laborious and subjective. To overcome such disadvantages, numerous MI detection techniques including signal processing and artificial intelligence tools have been developed. In this study, we propose a novel technique for automatic detection of MI based on disparity of cardiac system dynamics and synthesis of the standard 12-lead and Frank XYZ leads. First, 12-lead ECG signals are synthesized with Frank XYZ leads to build a hybrid 4-dimensional cardiac vector, which is decomposed into a series of proper rotation components (PRCs) by using the intrinsic time-scale decomposition (ITD) method. The novel cardiac vector may fully reflect the pathological alterations provoked by MI and may be correlated to the disparity of cardiac system dynamics between healthy and MI subjects. ITD is employed to measure the variability of cardiac vector and the first PRCs are extracted as predominant PRCs which contain most of the cardiac vector's energy. Second, four levels discrete wavelet transform with third-order Daubechies (db3) wavelet function is employed to decompose the predominant PRCs into different frequency bands, which combines with three-dimensional phase space reconstruction to derive features. The properties associated with the cardiac system dynamics are preserved. Since the frequency components above 40 Hz are lack of use in ECG analysis, in order to reduce the feature dimension, the advisable sub-band (D4) is selected for feature acquisition. Third, neural networks are then used to model, identify and classify cardiac system dynamics between normal (healthy) and MI cardiac vector signals. The difference of cardiac system dynamics between healthy control and MI cardiac vector is computed and used for the detection of MI based on a bank of estimators. Finally, experiments are carried out on the PhysioNet PTB database to assess the effectiveness of the proposed method, in which conventional 12-lead and Frank XYZ leads ECG signal fragments from 148 patients with MI and 52 healthy controls were extracted. By using the tenfold cross-validation style, the achieved average classification accuracy is reported to be 98.20%. Results verify the effectiveness of the proposed method which can serve as a potential candidate for the automatic detection of MI in the clinical application.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10374507PMC
http://dx.doi.org/10.1007/s11571-022-09870-7DOI Listing

Publication Analysis

Top Keywords

cardiac system
20
system dynamics
20
cardiac vector
20
frank xyz
12
xyz leads
12
cardiac
11
myocardial infarction
8
ecg signals
8
automatic detection
8
detection based
8

Similar Publications