Aims: The present guidelines advise replacing the aortic valve for individuals with severe aortic stenosis (AS) based on various echocardiographic parameters. Accurate measurements are essential to avoid misclassification and unnecessary interventions. The objective of this study was to evaluate the influence of measurement error on the echocardiographic evaluation of the severity of AS.
Methods And Results: A systematic review was performed to examine whether measurement errors are reported in studies focusing on the prognostic value of peak aortic jet velocity (V ), mean pressure gradient (MPG), and effective orifice area (EOA) in asymptomatic patients with AS. Out of the 37 studies reviewed, 17 (46%) acknowledged the existence of measurement errors, but none of them utilized methods to address them. Secondly, the magnitude of potential errors was collected from available literature for use in clinical simulations. Interobserver variability ranged between 0.9% and 8.3% for V and MPG but was higher for EOA (range 7.7%-12.7%), indicating lower reliability. Assuming a circular left ventricular outflow tract area led to a median underestimation of EOA by 23% compared to planimetry by other modalities. A clinical simulation resulted in the reclassification of 42% of patients, shifting them from a diagnosis of severe AS to moderate AS.
Conclusions: Measurement errors are underreported in studies on echocardiographic assessment of AS severity. These errors can lead to misclassification and misdiagnosis. Clinicians and scientists should be aware of the implications for accurate clinical decision-making and assuring research validity.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/echo.15664 | DOI Listing |
JMIR Biomed Eng
August 2025
Cardiovascular Center and Divisions of Cardiology and Hospital Medicine, Department of Internal Medicine, National Taiwan University Hospital, No.7, Chung Shan S Rd, Taipei, 100225, Taiwan, 886 2-2312-3456.
Background: Photoplethysmography (PPG) signals captured by wearable devices can provide vascular age information and support pervasive and long-term monitoring of personal health condition.
Objective: In this study, we aimed to estimate brachial-ankle pulse wave velocity (baPWV) from wrist PPG and electrocardiography (ECG) from smartwatch.
Methods: A total of 914 wrist PPG and ECG sequences and 278 baPWV measurements were collected via the smartwatch from 80 men and 82 women with average age of 63.
J Foot Ankle Res
September 2025
Department of Exercise Sciences, Brigham Young University, Provo, Utah, USA.
Introduction: Intrinsic foot muscles and the plantar fascia are crucial for foot health, which diminishes with age and conditions such as chronic plantar fasciitis (PF). Ultrasound (US) is an accessible and cost-effective method for evaluating these structures. This study aims to assess the repeatability, reliability, and validity of plantar fascia thickness and flexor digitorum brevis (FDB) muscle measurements using US compared with MRI in individuals with and without PF.
View Article and Find Full Text PDFMagn Reson Med
September 2025
Department of Biomedical Engineering, University of California, Davis, Davis, California, USA.
Purpose: This study sought to determine the intrasession repeatability of the diffusion-weighted (DW) arterial spin labeling (ASL) sequence at different postlabel delays (PLDs).
Methods: We first performed numerical simulations to study the accuracy of the two-compartment water exchange rate (Kw) fitting model with added Gaussian noise for DW PLDs at 1500, 1800, and 2100 ms. Ten young, healthy participants then underwent a structural T scan and two intrasession in vivo DW ASL scans at each PLD on a 3T MRI.
Rapid Commun Mass Spectrom
December 2025
Department of Pharmacy, The Affiliated Hospital of Xuzhou Medical University, Xuzhou, China.
Rationale: Chrysotoxine, a bibenzyl derivative from the stems of Dendrobium medicinal herbs, has recently emerged as a promising therapeutic candidate for cervical cancer. This study aimed to characterize chrysotoxine metabolites across multiple hepatocyte species and in rat urine.
Methods: Metabolites were identified and characterized using liquid chromatography coupled with benchtop Orbitrap high-resolution mass spectrometry (LC-Orbitrap-MS/MS) combined with Compound Discoverer software.
Nature
September 2025
Department of Physics, Harvard University, Cambridge, MA, USA.
Quantum simulations of many-body systems are among the most promising applications of quantum computers. In particular, models based on strongly correlated fermions are central to our understanding of quantum chemistry and materials problems, and can lead to exotic, topological phases of matter. However, owing to the non-local nature of fermions, such models are challenging to simulate with qubit devices.
View Article and Find Full Text PDF