A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Solvatochromic sensors detect proteome aggregation in stressed liver tissues with hepatic cancer and cirrhosis. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Protein misfolding and aggregation involve complex cellular processes with clinical implications in various diseases. However, the detection of aggregated proteomes without defined 3-D structures in a complex biological milieu is challenging. This study utilizes chromone scaffold-based environment-sensitive fluorophores P1 and P2 to detect misfolded and aggregated proteome in stressed liver cells and the liver tissues diseased patients. The reported crystallization induced emission probes (P1 and P2) exhibit both polarity and viscosity sensitivity, with emission intensity and wavelength linearly correlated to viscosity and polarity. Meanwhile, P1 and P2 selectively and generally fluoresce upon binding to various aggregated proteins. In hepatic cells, P2 outperforms P1 in detecting stress-induced global proteome aggregation. In mouse liver tissue upon drug-induced injury, the fluorescence intensity of P2 correlated with the severity of liver injury, serving as an earlier indicator for liver stress prior to ALT/AST increase. The quantification of emission wavelength reveals lower micro-environmental polarity in liver-injury tissue. In patient-derived tissues with hepatic cancer and cirrhosis, P1 and P2 also report on the presence of aggregated proteome. Together, the reported solvatochromic proteome aggregation sensors can detect hepatic proteome aggregation and analyze its local polarity in cultured cell lines, animal model tissues, and human clinical samples.

Download full-text PDF

Source
http://dx.doi.org/10.1039/d3tb00984jDOI Listing

Publication Analysis

Top Keywords

proteome aggregation
16
sensors detect
8
stressed liver
8
liver tissues
8
tissues hepatic
8
hepatic cancer
8
cancer cirrhosis
8
aggregated proteome
8
proteome
6
liver
6

Similar Publications