98%
921
2 minutes
20
Background: This study aimed to assess the accuracy of digital workflow for guided insertion of miniscrews in the anterior palate using restorative implant dentistry software and licensed software for orthodontic applications.
Methods: Twenty subjects (8 males, 12 females, mean age = 16.7 ± 2.1 years) were prospectively selected to receive guided insertion of bicortical palatal miniscrews. Virtual planning was performed using restorative implant dentistry software (Blue Sky Plan*, version 4.7) (group 1 = 10 subjects) and licensed orthodontic software (Dolphin Imaging Software, version 11.0) (group 2 = 10 subjects). A specific 3D Imaging technology was applied to permit the registration of the planned and achieved position of the miniscrews based on the superimposition of maxillary models. The angular deviation (accuracy error) between the planned and the achieved positions of the miniscrews were recorded. Independent Student's test was used with statistical significance set at p value < 0.05.
Results: The mean accuracy error recorded in group 1 was 7.15° ± 1.09 (right side) and 6.19 ± 0.80 (left side) while the mean error in group 2 was 6.74° ± 1.23 (right side) and 5.79 ± 0.95 (left side). No significant differences were recorded between the two groups (p > 0.05); instead, miniscrews placed on the right side were almost one degree higher than the left side (p < 0.05) in both groups.
Conclusions: The clinical accuracy error was similar when using generic and licensed orthodontic software for guided systems.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10353103 | PMC |
http://dx.doi.org/10.1186/s12903-023-03113-9 | DOI Listing |
Anal Chim Acta
November 2025
Key Laboratory of Analytical Science and Technology of Hebei Province, College of Chemistry and Materials Science, Hebei University, Baoding, 071002, PR China; Engineering Research Center of Ecological Safety and Conservation in Beijing-Tianjin-Hebei (Xiong'an New Area) of Ministry of Education, Bao
Background: In the contemporary era of rapid digital advancement, information security is closely associated with our daily life. From personal information to state secrets, all domains are intricately linked with information. Consequently, the significance of information security has garnered growing attention from an ever-increasing number of individuals.
View Article and Find Full Text PDFInt J Obstet Anesth
August 2025
Department of Liver Transplant Anaesthesia, Institute of Liver and Biliary Sciences, New Delhi, India.
Background: Epidural analgesia is the gold standard for labor pain relief, yet performing patient education remains challenging due to time constraints, language barriers, and variable health literacy. Traditional educational approaches often fail to ensure adequate patient understanding. Artificial intelligence (AI) interactive avatars offer a novel solution for delivering standardized, empathetic, and accessible patient education.
View Article and Find Full Text PDFTalanta
August 2025
Universidad de Buenos Aires. Facultad de Farmacia y Bioquímica. Departamento de Química Biológica, Junín 956, Buenos Aires, Argentina; Laboratorio de Biofísica Molecular, Instituto de Química y Fisicoquímica Biológicas, UBA - CONICET, Junín 956, Buenos Aires, Argentina. Electronic address:
The quantification of orthophosphate is essential for applications like water quality assessment, soil fertility analysis, metabolic monitoring and enzyme activity evaluation. Chemical quantification methods include the reaction between orthophosphate and molybdate under acidic conditions to form 12-molybdophosphoric acid units, which auto-assembles forming nanometer size particles. The adsorption of malachite green to these nanoparticles allows their spectrophotometric detection constituting one of the most widely used methods to quantify phosphate.
View Article and Find Full Text PDFSmall Methods
September 2025
Department of Pathology, College of Medicine, Hanyang University, Seoul, Republic of Korea.
While human epidermal growth factor receptor (HER2) has emerged as a tumor-agnostic biomarker, standard HER2 testing for anti-HER2 therapies using immunohistochemistry (IHC) and in situ hybridization (ISH) assays remains subjective, time-consuming, and often inaccurate. To address these limitations, an ultrafast and precise HER2 testing method is developed using Lab-On-An-Array (LOAA) digital real-time PCR (drPCR), a fully automated digital PCR enabling real-time absolute quantification. A multicenter study involving four independent breast cancer cohorts cross-validates the high diagnostic accuracy of drPCR-based HER2 assessment.
View Article and Find Full Text PDFJ Dent
September 2025
Maxillofacial Prosthodontist, Surgical Prosthodontist Private Practice Fort Lee, NJ, and Manhattan, New York, USA. Electronic address:
Objectives: Precise implant placement in the anterior and posterior maxilla often presents challenges due to variable bone and soft tissue anatomy. Many clinicians elect a freehand surgical approach because conventional surgical guides may not always be easy to design, fabricate, or utilize. Guided surgery has been proven to have advantages over freehand surgical protocols and therefore, the present study proposed utilizing the nasopalatine canal (NPC) as an anatomical reference and point of fixation for a novel rotational path surgical template during computer-aided implant surgery (CAIS).
View Article and Find Full Text PDF