Introduction: Hepatocellular carcinoma (HCC) is the second most common cause of cancer mortality worldwide. The risk factors associated with the development of HCC are chronic Hepatitis B, Hepatitis C, and alcoholic cirrhosis. The standard care for HCC is surgical resection but the scope is limited for some patients. Continuous advancement of radiation therapy enabled the technique of stereotactic body radiotherapy (SBRT) as an option for the treatment of those cases for which surgery cannot be done. According to recent literature and meta-analysis, SBRT is an optimum treatment method with high local control with low toxicity. In SBRT, radiation is delivered with a smaller number of fractions than conventional radiation and employs high-precision delivery and accuracy with the help of image guidance. From a series of retrospective and prospective studies, it has been confirmed that SBRT achieves excellent local control in patients with early-stage inoperable, intermediate-stage, and advanced diseases.
Background: A 42-year-old male patient related to HBeAg infection and high AFP levels developed HCC BCLC Stage A was admitted to our department. There were two lesions with PTV volumes of 41.07 cc and 9.573 cc with a distance between them of 3.51 cm. These two lesions were treated with a mono-isocentric VMAT planning with SBRT technique. In this case, we present an unusual clinical practice of mono-isocentric treatment planning for treating multiple liver lesions. Since radiation therapy was viewed as the primary form of treatment because the patient wasn't an ideal candidate for surgery, SBRT was selected as the patient's primary modality of treatment because of the tiny volume of the two lesions and the normal liver volume (>700cc). Triple-phase 4DCT was performed for simulation to account for the motion of target volume and normal structures. After delineating the target volume and other normal structures, treatment planning was done with a dose of 45 Gray which was to be delivered in 5 fractions. Two PTVs were created with a margin of 3.0 mm to IGTV. Considering the positions of the lesions, a single isocentre plan was created using a 6MV FFF photon beam for both the PTVs with the VMAT technique. The treatment was carried through with 3 arcs, one coplanar, and the other 2 non-coplanar. At the time of treatment, after the proper positioning of the patient, one CBCT image was taken to match with the planned CT image acquired at the time of the simulation. After applying the translational and rotational errors, the patient was treated.
Results: The patient was treated successfully. After treatment, the condition of the patient was normal, and no toxicities have been observed in follow-up.
Conclusion: Mono isocentric VMAT planning can be used for closely spaced lesions considering the position of lesions and other normal structures in the vicinity.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jmir.2023.06.005 | DOI Listing |
Med Phys
September 2025
Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital and University of Bern, Bern, Switzerland.
Background: Radiotherapy workflows conventionally deliver one treatment plan multiple times throughout the treatment course. Non-coplanar techniques with beam angle optimization or dosimetrically optimized pathfinding (DOP) exploit additional degrees of freedom to improve spatial conformality of the dose distribution compared to widely used techniques like volumetric-modulated arc therapy (VMAT). The temporal dimension of dose delivery can be exploited using multiple plans (sub-plans) within one treatment course.
View Article and Find Full Text PDFJ Appl Clin Med Phys
September 2025
Department of Radiation Oncology, Fudan University Shanghai Cancer Center, Department of Oncology, Shanghai Clinical Research Center for Radiation Oncology, Shanghai Key Laboratory of Radiation Oncology, Shanghai Medical College, Fudan University, Shanghai, China.
Purpose: This study aims to assess percentage of automated AIO plans that met clinical treatment standards of radiotherapy plans generated by the fully automated All-in-one (AIO) process.
Methods: The study involved 117 rectal cancer patients who underwent AIO treatment. Fully automated regions of interest (ROI) and treatment plans were developed without manual intervention, comparing them to manually generated plans used in clinical practice.
J Appl Clin Med Phys
September 2025
Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia, USA.
Purpose: Real‑time magnetic resonance-guided radiation therapy (MRgRT) integrates MRI with a linear accelerator (Linac) for gating and adaptive radiotherapy, which requires robust image‑quality assurance over a large field of view (FOV). Specialized phantoms capable of accommodating this extensive FOV are therefore essential. This study compares the performance of four commercial MRI phantoms on a 0.
View Article and Find Full Text PDFJ Appl Clin Med Phys
September 2025
Icon Cancer Centre Toowoomba, Toowoomba, Queensland, Australia.
Introduction: The role of imaging in radiotherapy is becoming increasingly important. Verification of imaging parameters prior to treatment planning is essential for safe and effective clinical practice.
Methods: This study described the development and clinical implementation of ImageCompliance, an automated, GUI-based script designed to verify and enforce correct CT and MRI parameters during radiotherapy planning.
J Appl Clin Med Phys
September 2025
Department of Radiation Oncology, University of Utah, Salt Lake City, Utah, USA.
Purpose: The development of on-board cone-beam computed tomography (CBCT) has led to improved target localization and evaluation of patient anatomical change throughout the course of radiation therapy. HyperSight, a newly developed on-board CBCT platform by Varian, has been shown to improve image quality and HU fidelity relative to conventional CBCT. The purpose of this study is to benchmark the dose calculation accuracy of Varian's HyperSight cone-beam computed tomography (CBCT) on the Halcyon platform relative to fan-beam CT-based dose calculations and to perform end-to-end testing of HyperSight CBCT-only based treatment planning.