Article Abstract

Background: Single-use (SU) ancillaries for cup preparation in total hip arthroplasty (THR) aim to reduce the costs of hip replacement surgery. These devices have been recently introduced, but their safety and feasibility have not been studied. Therefore, we performed a prospective randomized study aiming to assess the impact in our department of using these SU ancillaries versus standard reusable ancillaries for dual mobility THR regarding 1) the cost, 2) operative time, 3) quality of primary fixation.

Hypothesis: We hypothesized that the use of SU ancillaries for acetabular preparation would reduce maintenance costs, and so optimise the operating procedure, reduce the overall cost of surgery, save time, while maintaining the same quality of prosthesis fitting.

Method: We conducted a randomised, controlled, open-label, two-arm, single-centre, prospective therapeutic trial with a medico-economic objective. Inclusions were made prospectively from patients hospitalised and surgically managed in our department for arthrosis over 18 years old treated with dual mobility THR.

Results: In the current study, 18/20 (90%) of the cases required the use of one SU reamer when using SU ancillaries. Only two cases (10%) required a second SU reamer (without SU failure regarding the acetabular implant) because there was too much subchondral bone left and not enough cancellous bone allowing correct cup fitting. We also found that the test implant supplied in the SU kit had a less secure press-fit than the reusable metal test implants. There was one of primary press-fit failure in the SU group requiring a different cup with additional screws. The estimated cost to the supplier per procedure was 20,105 euros using single-use reamers versus 26,666 euros using conventional ancillary kits, a saving of 6561 euros (p<0.001). For the healthcare institution, the median price per intervention on the differentiating points was 2648 euros versus 2580 euros, with no significant difference (p=0.297). The results show an average societal cost of 52,199 euros using single-use and 53,572 euros using reusable ancillary equipment, with a significant difference between the two groups (p<0.003). The average cost of Healthcare Risk Waste (HCRW) disposal in the SU group was 5.2 euros per intervention against 5.1 euros in the RU group, without significant difference (p=0.910). We found a similar result for the cost of disposal of non-HCRW waste per procedure: 0.37 euros in the SU group versus 0.34 in the RU group, without significant difference (p=0.345).

Conclusion: SU ancillaries significantly reduce the table set up time and have the potential to facilitate time and cost savings but further research is needed in this direction. Our study shows that the daily workload, operating times, and the number of boxes of instruments to be sterilised are decreased. The associated environmental gain is significant. Nevertheless, the economic promise of these SU ancillaries is only partially supported in this trial owing to the small number of patients. Further work will be needed to obtain a more powerful medico-economic assessment of this promising ancillary product.

Level Of Evidence: II; prospective randomized study.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.otsr.2023.103658DOI Listing

Publication Analysis

Top Keywords

dual mobility
12
reusable ancillaries
8
ancillaries dual
8
total hip
8
hip replacement
8
prospective randomized
8
safety feasibility
8
ancillaries
6
single-use versus
4
versus reusable
4

Similar Publications

Transcription initiation factor TFIID subunit 1 (TAF1) is a pivotal component of the TFIID complex, critical for RNA polymerase II-mediated transcription initiation. However, the molecular basis by which TAF1 recognizes and associates with chromatin remains incompletely understood. Here, we report that the tandem bromodomain module of TAF1 engages nucleosomal DNA through a distinct positively charged surface patch on the first bromodomain (BD1).

View Article and Find Full Text PDF

Complementary Separation of Novel Synthetic Opioids.

J Am Soc Mass Spectrom

September 2025

Department of Chemistry and Biochemistry, Florida International University, Miami, Florida 33199, United States.

The escalating prevalence and diversity of fentanyl analogues poses an immediate concern for the global community. Fentanyl and its analogues are the primary contributors to both fatal and nonfatal overdoses in the United States. The most recent instances of fentanyl-related overdoses have been attributed to the illicit production of fentanyl, characterized by its exceptionally potent nature.

View Article and Find Full Text PDF

Ultrafast Al⁺ Conduction through Cooperative Bonding in Disordered Polycarbonate-Polyether Electrolytes.

Small Methods

September 2025

Hebei Key Laboratory of Optic-Electronic Information and Materials, National & Local Joint Engineering Laboratory of New Energy Photoelectric Devices, College of Physics, Science and Technology, Hebei University, Baoding, 071002, China.

As a new generation of high-energy-density energy storage system, solid-state aluminum-ion batteries have attracted much attention. Nowadays polyethylene oxide (PEO)-based electrolytes have been initially applied to Lithium-ion batteries due to their flexible processing and good interfacial compatibility, their application in aluminum-ion batteries still faces problems. To overcome the limitations in aluminum-ion batteries-specifically, strong Al coordination suppressing ion dissociation, high room-temperature crystallinity, and inadequate mechanical strength-this study develops a blended polymer electrolyte (BPE) of polypropylene carbonate (PPC) and PEO.

View Article and Find Full Text PDF

RgMYC2 promotes catalpol biosynthesis by regulating Rg10HGO in Rehmannia glutinosa.

Plant Sci

September 2025

College of Life Sciences, Henan Normal University, Xinxiang 453007, China; Henan International Joint Laboratory of Aquatic Toxicology and Health Protection, College of Life Sciences, Henan Normal University, Xinxiang 453007, China. Electronic address:

Catalpol, one of the major bioactive components in the traditional Chinese medicinal herb Rehmannia glutinosa, exhibits multiple pharmacological activities such as hypoglycemic and neuroprotective effects. Consequently, mechanistic elucidation of catalpol biosynthesis regulation in R. glutinosa is critically important.

View Article and Find Full Text PDF

Surgical approach does not influence instability risk in primary total hip arthroplasty with monobloc dual mobility cup.

J Arthroplasty

September 2025

Orthopaedic Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital, 69004, Lyon, France; University of Lyon, Claude Bernard Lyon 1 University, IFSTTAR, LBMC UMR_T9406, 69622, Lyon, France.

Background: The impact of the surgical approach on the risk of dislocation in total hip arthroplasty (THA) remains controversial, particularly when monobloc dual mobility cups (DMCs) are used. This study aimed to compare dislocation and complication rates between the postero-lateral and direct anterior approaches with a DMC in primary elective THA, based on data collected from a single center.

Methods: Between 2010 and 2022, 1,378 consecutive primary THAs were performed using a monobloc DMC.

View Article and Find Full Text PDF