Article Abstract

Spheroid-on-a-chip platforms are emerging as promising in vitro models that enable screening of the efficacy of biologically active ingredients. Generally, the supply of liquids to spheroids occurs in the steady flow mode with the use of syringe pumps; however, the utilization of tubing and connections, especially for multiplexing and high-throughput screening applications, makes spheroid-on-a-chip platforms labor- and cost-intensive. Gravity-induced flow using rocker platforms overcomes these challenges. Here, a robust gravity-driven technique was developed to culture arrays of cancer cell spheroids and dermal fibroblast spheroids in a high-throughput manner using a rocker platform. The efficiency of the developed rocker-based platform was benchmarked to syringe pumps for generating multicellular spheroids and their use for screening biologically active ingredients. Cell viability, internal spheroid structure as well as the effect of vitamin C on spheroids' protein synthesis was studied. The rocker-based platform not only offers comparable or enhanced performance in terms of cell viability, spheroids formation, and protein production by dermal fibroblast spheroids but also, from a practical perspective, offers a smaller footprint, requires a lower cost, and offers an easier method for handling. These results support the application of rocker-based microfluidic spheroid-on-a-chip platforms for in vitro screening in a high-throughput manner with industrial scaling-up opportunities.

Download full-text PDF

Source
http://dx.doi.org/10.1002/biot.202200621DOI Listing

Publication Analysis

Top Keywords

spheroid-on-a-chip platforms
12
rocker platform
8
biologically active
8
active ingredients
8
syringe pumps
8
dermal fibroblast
8
fibroblast spheroids
8
high-throughput manner
8
rocker-based platform
8
cell viability
8

Similar Publications

The development of in vitro models recapitulating nanoparticle transport under physiological flow conditions is of great importance for predicting the efficacy of nanoparticle drug carriers. Liposomes are extensively used for drug delivery owing to their biocompatibility and biodegradability and the ability to carry both hydrophilic and hydrophobic compounds. Here, we used a library of liposomes with various dimensions and a microfluidic platform comprising a large array of uniformly sized breast cancer spheroids to explore size-dependent liposome internalization and retention in the spheroids under close-to-physiological interstitial conditions.

View Article and Find Full Text PDF

Spheroid-on-a-chip platforms are emerging as promising in vitro models that enable screening of the efficacy of biologically active ingredients. Generally, the supply of liquids to spheroids occurs in the steady flow mode with the use of syringe pumps; however, the utilization of tubing and connections, especially for multiplexing and high-throughput screening applications, makes spheroid-on-a-chip platforms labor- and cost-intensive. Gravity-induced flow using rocker platforms overcomes these challenges.

View Article and Find Full Text PDF

Spheroids are recognized for resembling the important characteristics of natural tumors in cancer research. However, the lack of controllability of the spheroid size, form, and density in conventional spheroid culture methods reduces the reproducibility and precision of bioassay results and the assessment of drug-dose responses in spheroids. Nonetheless, the accurate prediction of cellular responses to drug compounds is crucial for developing new efficient therapeutic agents and optimizing existing therapeutic strategies for personalized medicine.

View Article and Find Full Text PDF

Microfluidic tumour spheroid-on-a-chip platforms enable control of spheroid size and their microenvironment and offer the capability of high-throughput drug screening, but drug supply to spheroids is a complex process that depends on a combination of mechanical, biochemical, and biophysical factors. To account for these coupled effects, many microfluidic device designs and operating conditions must be considered and optimized in a time- and labour-intensive trial-and-error process. Computational modelling facilitates a systematic exploration of a large design parameter space in silico simulations, but the majority of in silico models apply only a small set of conditions or parametric levels.

View Article and Find Full Text PDF

Vascularization of iNSC spheroid in a 3D spheroid-on-a-chip platform enhances neural maturation.

Biotechnol Bioeng

February 2022

Adult Stem Cell Research Center and Research Institute for Veterinary Science, College of Veterinary Medicine, Seoul National University, Seoul, South Korea.

In vitro platforms for studying the human brain have been developed, and brain organoids derived from stem cells have been studied. However, current organoid models lack three-dimensional (3D) vascular networks, limiting organoid proliferation, differentiation, and apoptosis. In this study, we created a 3D model of vascularized spheroid cells using an injection-molded microfluidic chip.

View Article and Find Full Text PDF