A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Improving Single-Molecule Antibody Detection Selectivity through Optimization of Peptide Epitope Presentation in OmpG Nanopore. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Outer membrane protein G (OmpG) is a monomeric porin found in , which possesses seven flexible loops. OmpG has been engineered as a nanopore sensor, where its loops can host affinity epitopes for selective detection of biological molecules. In this study, we investigated various loop positions to incorporate a FLAG peptide antigen epitope in the most flexible loop 6 and tested the efficacy and sensitivity of these nanopore constructs in antibody detection. We observed an OmpG construct containing inserted FLAG sequence, which exhibited strong interaction with anti-FLAG antibodies in flow cytometry; however, it could not translate molecule interactions into a readable signal in current recordings. Further optimization of the peptide presentation strategy by replacing specific sections of loop 6 sequences with the FLAG tag created a construct capable of generating unique and distinct signals when interacting with various monoclonal or polyclonal anti-FLAG clones IgG antibodies in the mixture. The peptide display scheme demonstrated in this study can be generalized for the engineering of OmpG sensors, which can be used for screening and validating positive clones during antibody development, as well as for real-time quality control of cell cultures in monoclonal antibody production.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acssensors.3c00528DOI Listing

Publication Analysis

Top Keywords

antibody detection
8
optimization peptide
8
ompg
5
improving single-molecule
4
antibody
4
single-molecule antibody
4
detection selectivity
4
selectivity optimization
4
peptide
4
peptide epitope
4

Similar Publications