Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
This article presents a body-heat-powered, multi-sensor SoC for measurement of chemical and biological sensors. Our approach combines analog front-end sensor interfaces for voltage- (V-to-I) and current-mode (potentiostat) sensors with a relaxation oscillator (RxO) readout scheme targeting << 10 μW power consumption. The design was implemented as a complete sensor readout system-on-chip, including a low-voltage energy harvester compatible with thermoelectric generation and a near-field wireless transmitter. A prototype IC was fabricated in a 0.18 μm CMOS process as a proof-of-concept. As measured, full-range pH measurement consumes 2.2 μW at maximum, where the RxO consumes 0.7 μW and measured linearity of the readout circuit demonstrates R 0.999. Glucose measurement is also demonstrated using an on-chip potentiostat circuit as the input of the RxO, with a readout power consumption as low as 1.4 μ W. As a final proof-of-principle, both pH and glucose measurement are demonstrated while powering from body heat using a centimeter-scale thermoelectric generator on the skin surface, and pH measurement is further demonstrated with an on-chip transmitter for wireless data transmission. Long-term, the presented approach may enable a variety of biological, electrochemical, and physical sensor readout schemes with microwatt operation for batteryless and power autonomous sensor systems.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10613511 | PMC |
http://dx.doi.org/10.1109/TBCAS.2023.3286348 | DOI Listing |