Programmed intermittent epidural bolus as an ideal method for labor analgesia: a randomized controlled trial.

Korean J Anesthesiol

Department of Anesthesiology and Pain Medicine, Dongtan Sacred Heart Hospital, Hallym University School of Medicine, Hwaseong, Korea.

Published: February 2024


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Although programmed intermittent epidural bolus (PIEB) is effective for labor analgesia, an appropriate flow rate has not been established. Therefore, we investigated the analgesic effect based on different epidural injection flow rates.

Methods: Nulliparous women scheduled for spontaneous labor were enrolled in this randomized trial. After injection of intrathecal 0.2% ropivacaine 3 mg with fentanyl 20 μg, participants were randomized to three study groups. Epidural analgesics, 10 ml during one hour, were administered with patient controlled epidural analgesia as follows (0.2% ropivacaine 60 ml, fentanyl 180 μg, and 0.9% saline 40 ml): continuous (n = 28, 10 ml/h for continuous infusion), PIEB (n = 29, 240 ml/h for bolus infusion of 10 ml), or manual (n = 28, 1200 ml/h for bolus injection of 10 ml). The primary outcome was hourly consumption of the epidural solution. The time interval between labor analgesia and the first breakthrough pain was investigated.

Results: The median (Q1, Q3) hourly consumption of epidural anesthetics was significantly different among the groups (continuous: 14.3 [8.7, 16.9] ml, PIEB: 9.4 [6.2, 9.8] ml, manual: 8.6 [7.6, 9.9] ml; P < 0.001). The time to breakthrough pain for the PIEB group was longer than that for the other groups (continuous: 78.5 [35.8, 185.0] min, PIEB: 200.0 [88.5, 441.5] min, manual: 60.5 [37.3, 162.0] min, P = 0.027).

Conclusions: PIEB, with a low-flow rate, provided more adequate labor analgesia than a continuous epidural infusion or manual injection with a high-flow rate.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10834717PMC
http://dx.doi.org/10.4097/kja.23173DOI Listing

Publication Analysis

Top Keywords

labor analgesia
16
programmed intermittent
8
epidural
8
intermittent epidural
8
epidural bolus
8
02% ropivacaine
8
ropivacaine fentanyl
8
ml/h bolus
8
infusion manual
8
hourly consumption
8

Similar Publications

Study Objective: This study evaluated whether ultrasound-guided serratus anterior plane block (SAPB) provided non-inferior analgesic effects for minimally invasive pectus excavatum repair surgery compared with thoracic paravertebral block (TPVB).

Design: A noninferiority randomized trial.

Setting: West China Hospital of Sichuan University.

View Article and Find Full Text PDF

Low-Dose Ropivacaine-Fentanyl Spinal Anesthesia Combined with Carbetocin for Cesarean Section: A Randomized Double-Blind Non-Inferiority Trial.

J Pain Res

September 2025

Department of National Institute of Traditional Chinese Medicine Constitution and Preventive Medicine, Beijing University of Chinese Medicine, Beijing, People's Republic of China.

Purpose: Intrathecal fentanyl improves intraoperative analgesia and reduces hypotension by enhancing subtherapeutic local anesthetic doses during cesarean sections. This study explores whether these advantages are affected by the negative circulatory effects of carbetocin after delivery.

Patients And Methods: This randomized double-blind, non-inferiority trial was conducted at a tertiary hospital in China.

View Article and Find Full Text PDF

Introduction:  Breast cancer incidence has been rising in recent years, particularly among younger women, and it is now the leading cancer among Indian females. Acute postoperative pain is a significant concern, often deterring patients from surgery. Combining regional anesthesia with intravenous analgesics can improve postoperative outcomes.

View Article and Find Full Text PDF

Effect of Epidural Catheter Design on Analgesic Efficacy During Programmed Intermittent Epidural Boluses: A Randomized Double-Blinded Controlled Trial.

Drug Des Devel Ther

September 2025

Department of anesthesiology, Obstetrics & Gynecology Hospital of Fudan University, Shanghai Key Lab of Reproduction and Development, Shanghai Key Lab of Female Reproductive Endocrine Related Diseases, Shanghai, 200433 People's Republic of China.

Purpose: To compare analgesic outcomes between single- and multi-orifice epidural catheters at a 360-mL/h delivery rate during programmed intermittent epidural bolus.

Patients And Methods: In this prospective randomized double-blinded controlled trial, 102 healthy nulliparous parturients requesting labor analgesia at the Shanghai First Maternity and Infant Hospital were enrolled from July to September 2023. Participants were given either single- or multi-orifice catheters for epidural analgesia (0.

View Article and Find Full Text PDF

The Analgesic Efficacy of Liposomal Bupivacaine in Adductor Canal Block Following Knee Arthroplasty: A Single-Center, Prospective, Randomized and Controlled Clinical Trial.

Drug Des Devel Ther

September 2025

Department of Anesthesiology, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, Anhui, People's Republic of China.

Purpose: This study aimed to compare the analgesic efficacy of liposomal bupivacaine with that of traditional ropivacaine in adductor canal blocks for patients undergoing knee arthroplasty.

Patients And Methods: A total of 119 consenting participants, who were scheduled for elective knee arthroplasty (including total knee replacement and unicompartmental knee replacement) under general anesthesia, were randomly assigned to either receive an ultrasound-guided adductor canal block with ropivacaine or liposomal bupivacaine. The primary endpoint of this study was the pain scores at 2, 24, 48, and 72 hours post-surgery.

View Article and Find Full Text PDF