Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Age-related changes in cerebral hemodynamics are controversial and discrepancies may be due to experimental techniques. As such, the purpose of this study was to compare cerebral hemodynamics measurements of the middle cerebral artery (MCA) between transcranial Doppler ultrasound (TCD) and four-dimensional flow MRI (4D flow MRI). Twenty young (25 ± 3 years) and 19 older (62 ± 6 years) participants underwent two randomized study visits to evaluate hemodynamics at baseline (normocapnia) and in response to stepped hypercapnia (4% CO, and 6% CO) using TCD and 4D flow MRI. Cerebral hemodynamic measures included MCA velocity, MCA flow, cerebral pulsatility index (PI) and cerebrovascular reactivity to hypercapnia. MCA flow was only assessed using 4D flow MRI. MCA velocity between the TCD and 4D flow MRI methods was positively correlated across the normocapnia and hypercapnia conditions ( = 0.262; = 0.004). Additionally, cerebral PI was significantly correlated between TCD and 4D flow MRI across the conditions ( = 0.236; = 0.010). However, there was no significant association between MCA velocity using TCD and MCA flow using 4D flow MRI across the conditions ( = 0.079; = 0.397). When age-associated differences in cerebrovascular reactivity using conductance were compared using both methodologies, cerebrovascular reactivity was greater in young adults compared to older adults when using 4D flow MRI (2.11 ± 1.68 mL/min/mmHg/mmHg vs. 0.78 ± 1.68 mL/min/mmHg/mmHg; = 0.019), but not with TCD (0.88 ± 1.01 cm/s/mmHg/mmHg vs. 0.68 ± 0.94 cm/s/mmHg/mmHg; = 0.513). Our results demonstrated good agreement between the methods at measuring MCA velocity during normocapnia and in response to hypercapnia, but MCA velocity and MCA flow were not related. In addition, measurements using 4D flow MRI revealed effects of aging on cerebral hemodynamics that were not apparent using TCD.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10250020PMC
http://dx.doi.org/10.3389/fphys.2023.1198615DOI Listing

Publication Analysis

Top Keywords

flow mri
40
mca velocity
20
cerebral hemodynamics
16
mca flow
16
flow
14
tcd flow
12
cerebrovascular reactivity
12
mri
10
mca
10
cerebral
8

Similar Publications

Congenital intrahepatic portosystemic shunts are uncommon vascular anomalies that can lead to hyperammonemia and liver dysfunction. We report a 48-year-old woman with a large intrahepatic shunt presenting with elevated blood ammonia and progressive hepatic atrophy. She underwent percutaneous coil-in-plug embolization using an Amplatzer Vascular Plug II filled with coils.

View Article and Find Full Text PDF

Fungal cerebral aneurysms, particularly those resulting from direct invasion by fungal sinusitis, are rare and often fatal when involving the cavernous segment of the internal carotid artery (ICA). We present a case of a ruptured fungal ICA aneurysm caused by sinusitis, successfully treated with parent artery occlusion (PAO). In this case, an 80-year-old woman presented with right ptosis, facial pain, and cranial nerve III, IV, and VI palsies.

View Article and Find Full Text PDF

Application of high-resolution cone-beam computed tomography for evaluation of endothelialization after flow diverter implantation for unruptured intracranial aneurysms.

AJNR Am J Neuroradiol

September 2025

From the Department of Interventional Radiology (Shuailong Shi, Shuhai Long, Ji Ma, Peijie Lu, Jie Yang, Ye Wang, Tengfei Li), The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China; The School of Life Science and Technology (Zhike Zhang), Xi'an Jiaotong University, Xi'an, China; an

Background And Purpose: Although high-resolution cone-beam computed tomography (HR-CBCT) is used for immediate evaluation of stent apposition, studies using this technique to evaluate flow diverter (FD) endothelialization during follow-up are limited. The study aims to investigate the potential of HR-CBCT in assessing FD endothelialization and identify factors influencing poor endothelialization.

Materials And Methods: The clinical and imaging data of patients with unruptured intracranial aneurysms (UIAs) treated by FDs from March 2019 to October 2023 were retrospectively analyzed.

View Article and Find Full Text PDF

Fetal 4D Flow CMR for Advanced Diagnostics of Congenital Heart Disease: A Prospective Cohort Study.

Eur Heart J Cardiovasc Imaging

September 2025

Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany.

Aims: Fetal circulation undergoes complex changes in congenital heart disease (CHD) that are challenging to assess with fetal echocardiography. This study aimed to assess clinical feasibility and diagnostic value of 4D flow cardiac magnetic resonance (CMR) in fetal CHD.

Methods And Results: Pregnant women in advanced third trimester pregnancy with fetal CHD were prospectively recruited for fetal CMR between 08/2021 and 11/2024.

View Article and Find Full Text PDF

Full Free-Breathing Cardiac MRI: Enhancing Efficiency and Image Quality in Clinical Practice.

J Cardiovasc Magn Reson

September 2025

Department of Magnetic Resonance Imaging, Fuwai Hospital and National Center for Cardiovascular Diseases, Peking Union Medical College and Chinese Academy of Medical Sciences, Beijing 100037, China; Key Laboratory of Cardiovascular Imaging, Chinese Academy of Medical Sciences, Beijing 100730, China.

Background: Conventional cardiac magnetic resonance (CMR) examinations require patients to repeatedly hold their breath, which can reduce examination efficiency and pose challenges for patients unable to do so. This study aimed to demonstrate the feasibility and effectiveness of a full free-breathing CMR protocol in clinical practice.

Methods: Patients prospectively enrolled in this study underwent a full free-breathing CMR exam on a 3T scanner between June 1 and June 30, 2024.