Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: The current protocol for use of the image-guided adaptive brachytherapy (IGABT) procedure entails transport of a patient between the treatment room and the 3-D tomographic imaging room after implantation of the applicators in the body, which movement can cause position displacement of the applicator. Moreover, it is not possible to track 3-D radioactive source movement inside the body, even though there can be significant inter- and intra-fractional patient-setup changes. In this paper, therefore, we propose an online single-photon emission computed tomography (SPECT) imaging technique with a combined C-arm fluoroscopy X-ray system and attachable parallel-hole collimator for internal radioactive source tracking of every source position in the applicator.

Methods And Materials: In the present study, using Geant4 Monte Carlo (MC) simulation, the feasibility of high-energy gamma detection with a flat-panel detector for X-ray imaging was assessed. Further, a parallel-hole collimator geometry was designed based on an evaluation of projection image quality for a Ir point source, and 3-D limited-angle SPECT-image-based source-tracking performances were evaluated for various source intensities and positions.

Results: The detector module attached to the collimator could discriminate the Ir point source with about 3.4% detection efficiency when including the total counts in the entire deposited energy region. As the result of collimator optimization, hole size, thickness, and length were determined to be 0.5, 0.2, and 45 mm, respectively. Accordingly, the source intensities and positions also were successfully tracked with the 3-D SPECT imaging system when the C-arm was rotated within 110° in 2 seconds.

Conclusions: We expect that this system can be effectively implemented for online IGABT and in vivo patient dose verification.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.brachy.2023.05.003DOI Listing

Publication Analysis

Top Keywords

dose verification
8
monte carlo
8
carlo simulation
8
radioactive source
8
spect imaging
8
parallel-hole collimator
8
point source
8
source intensities
8
source
7
imaging
5

Similar Publications

Ethnopharmacological Relevance: Fever is a prevalent clinical symptom and is usually caused by inflammation or infection. Persistent high fever can lead to delirium, coma and convulsions, causing brain damage. Angong Niuhuang Pill (ANP), a traditional Chinese emergency medicine, has been employed in clinical practice for centuries, with well-documented antipyretic effects.

View Article and Find Full Text PDF

Purpose This study aimed to identify provider- and practice-level factors influencing human papillomavirus (HPV) vaccine uptake among Chinese American (CA) adolescents. Despite increasing public health efforts, HPV vaccination rates in this population remain suboptimal, and knowledge on the link between provider/practice characteristics and vaccine uptake is limited. Methods We analyzed data from 1,272 CA adolescents (aged 13-17) using the National Immunization Survey-Teen (2015-2019) datasets.

View Article and Find Full Text PDF

Background: Single-isocenter multiple-target (SIMT) treatments are a robust beam delivery technique involving modulated multileaf collimators for off-axis targets. SIMT requires quality assurance (QA) for both dosimetry and geometry to ensure accurate beam delivery according to the treatment plan. A primary challenge in SIMT QA is the need for phantoms capable of evaluating both dosimetric and geometric accuracy.

View Article and Find Full Text PDF

Background: As advanced treatment plans increasingly include optimizing both dose and linear energy transfer (LET), there is a growing demand for tools to measure LET in clinical settings. Although various detection systems have been investigated in this pursuit, the scarcity of detectors capable of providing per-ion data for a fast and streamlined verification of LET distributions remains an issue. Silicon pixel detector technology bridges this gap by enabling rapid tracking of single-ion energy deposition.

View Article and Find Full Text PDF

Background: Xuanshen decoction (XSD) is a traditional Chinese medicine formulation that is often applied in treating slow transit constipation (STC). However, its specific therapeutic mechanism remains to be characterized.

Aim: To investigate the mechanism of XSD for STC, we combined network pharmacology prediction, molecular docking analysis, and studies.

View Article and Find Full Text PDF