Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The primary sight control system of a tank gunner has image stabilization as one of its primary functions. The image stabilization deviation in the aiming line is a key indicator for evaluating the operational status of Gunner's Primary Sight control system. Employing image detection technology to measure image stabilization deviation enhances the effectiveness and accuracy of the detection process and allows for the evaluation of image stabilization functionality. Hence, this paper proposes an image detection method aimed at the Gunner's Primary Sight control system of a specific tank which utilizes an enhanced You Only Look Once version 5 (YOLOv5) sight-stabilizing deviation algorithm. At first, a dynamic weight factor is integrated into SCYLLA-IoU (), creating , which replaces Complete IoU () as the loss function of YOLOv5. After that, the Spatial Pyramid Pool module of YOLOv5 was enhanced to improve the multi-scale feature fusion ability of the model, thereby elevating the performance of the detection model. Finally, the C3CA module was created by embedding the Coordinate Attention (CA) attention mechanism into the CSK-MOD-C3 (C3) module. The Bi-directional Feature Pyramid (BiFPN) network structure was also incorporated into the Neck network of YOLOv5 to improve the model's ability to learn target location information and image detection accuracy. Based on data collected by a mirror control test platform, experimental results indicate an improvement in the detection accuracy of the model by 2.1%. These findings offer valuable insights into measuring the image stabilization deviation in the aiming line and facilitating the development of the parameter measurement system for Gunner's Primary Sight control system.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10255307PMC
http://dx.doi.org/10.3390/s23115039DOI Listing

Publication Analysis

Top Keywords

image stabilization
24
primary sight
20
image detection
16
stabilization deviation
16
gunner's primary
16
sight control
16
control system
16
image
10
detection method
8
deviation aiming
8

Similar Publications

Use of a masseter fascia transposition flap for ventral orbital stabilization after partial inferior orbitectomy in a dog.

Can Vet J

September 2025

Department of Clinical Sciences, College of Veterinary Medicine, Kansas State University, 1800 Denison Avenue, Manhattan, Kansas 66506, USA.

A 12-year-old neutered male pit bull crossbreed dog was presented because of a right caudal maxillary swelling. Computed tomographic imaging of the skull and revealed a right maxillary mass with lysis of the medial wall of the right orbit and rostral aspect of the zygomatic bone. A biopsy was done, and histopathology results were consistent with a mixed odontogenic tumor.

View Article and Find Full Text PDF

Computed Tomography's Impact on the Surgical Planning for Posterior Malleolar Fractures.

Rev Bras Ortop (Sao Paulo)

June 2025

Department of Orthopedics and Traumatology, Santa Casa de São Paulo - Pavilhão Fernandinho Simonsen, Faculdade de Ciências Médicas da Santa Casa de São Paulo, São Paulo, SP, Brazil.

Objective: This study aimed to evaluate the influence of computed tomography (CT) on the preoperative planning of posterior malleolus (PM) fractures of the ankle, comparing its information with that of conventional radiographs and assessing its impact on surgical treatment.

Methods: The study included 81 patients with PM fractures, whose radiological and CT images were analyzed by 33 specialized orthopedic surgeons. The study had two stages, with a radiological assessment on the first, and the second having radiological plus CT evaluation.

View Article and Find Full Text PDF

[Computed Tomography's Impact on the Surgical Planning for Posterior Malleolar Fractures].

Rev Bras Ortop (Sao Paulo)

June 2025

Departamento de Ortopedia e Traumatologia da Santa Casa de São Paulo - Pavilhão Fernandinho Simonsen, Faculdade de Ciências Médicas da Santa Casa de São Paulo, São Paulo, SP, Brasil.

Objective: The present study aimed to evaluate the influence of computed tomography (CT) on the preoperative planning of posterior malleolus (PM) fractures of the ankle, comparing its information with that of conventional radiographs and assessing its impact on surgical treatment.

Methods: The study included 81 patients with PM fractures, whose radiological and CT images were analyzed by 33 specialized orthopedic surgeons. The study had two stages, with a radiological assessment on the first, and the second having radiological and CT evaluation.

View Article and Find Full Text PDF

Background: The treatment of mandibular angle fractures remains controversial, particularly regarding the method of fixation. The primary aim of this study was to compare surgical outcomes following treatment with 1-plate versus 2-plate fixation across two oral and maxillofacial surgery clinics. The secondary aim was to evaluate associations between patient-, trauma-, and procedure-specific factors with postoperative complications and to identify high-risk patients for secondary osteosynthesis.

View Article and Find Full Text PDF

Deep learning approaches have improved disease diagnosis efficiency. However, AI-based decision systems lack sufficient transparency and interpretability. This study aims to enhance the explainability and training performance of deep learning models using explainable artificial intelligence (XAI) techniques for brain tumor detection.

View Article and Find Full Text PDF