Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Ex vivo hypothermic machine perfusion (HMP) is a strategy for controlling ischemia-reperfusion injury in donation after circulatory death (DCD) liver transplantation. The pH of blood increases with a decrease in temperature and water dissociation, leading to a decrease in [H]. This study aimed to verify the optimal pH of HMP for DCD livers. Rat livers were retrieved 30 min post-cardiac arrest and subjected to 3-h cold storage (CS) in UW solution (CS group) or HMP with UW-gluconate solution (machine perfusion [MP] group) of pH 7.4 (original), 7.6, 7.8, and 8.0 (MP-pH 7.6, 7.8, 8.0 groups, respectively) at 7-10 °C. The livers were subjected to normothermic perfusion to simulate reperfusion after HMP. All HMP groups showed greater graft protection compared to the CS group due to the lower levels of liver enzymes in the former. The MP-pH 7.8 group showed significant protection, evidenced by bile production, diminished tissue injury, and reduced flavin mononucleotide leakage, and further analysis by scanning electron microscopy revealed a well-preserved structure of the mitochondrial cristae. Therefore, the optimum pH of 7.8 enhanced the protective effect of HMP by preserving the structure and function of the mitochondria, leading to reduced reperfusion injury in the DCD liver.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10253457PMC
http://dx.doi.org/10.3390/jcm12113845DOI Listing

Publication Analysis

Top Keywords

machine perfusion
12
hypothermic machine
8
circulatory death
8
dcd liver
8
hmp
6
exploration optimal
4
optimal hypothermic
4
perfusion
4
perfusion rat
4
liver
4

Similar Publications

Background: Postoperative cognitive dysfunction (POCD) occurs in 20% to 80% of patients following cardiac surgical interventions. The incidence of delirium is from 20% to 50%. Impaired cerebral autoregulation (CA) during cardiopulmonary bypass (CPB) contributes to these issues.

View Article and Find Full Text PDF

Objectives: On-site normothermic machine perfusion of the liver may require hepatic arterial reconstruction. The effect of arterial reconstruction on the deve-lopment of primary ischemic cholangiopathy has not been fully elucidated in liver transplants with organs donated after circulatory death. The aim of this study was to evaluate the effect of normothermic machine perfusion with arterial reconstruction at the onset of ischemic cholangiopathy in liver transplants with organs donated after circulatory death.

View Article and Find Full Text PDF

The global shortage of suitable donor kidneys is the primary challenge in kidney transplantation, and it is exacerbated by ageing donors with increased numbers of health issues. Improving organ assessment, preservation and conditioning could enhance organ utilization and patient outcomes. Hypothermic machine perfusion (HMP) is associated with better results than static cold storage by reducing delayed graft function and improving short-term graft survival, especially in kidneys recovered from marginal-quality donors.

View Article and Find Full Text PDF

Static cold storage (SCS) on ice has remained the gold standard preservation method for heart transplantation, and prolonged cold ischemia outside the typical 4-6 hour window is associated with an increased risk of primary graft dysfunction - a consequence attributed to ischemic damage and reperfusion injury. This, unfortunately limits the travel radius for donor heart procurement, a key factor that contributes to the overall shortage of donor organs. Recent research and clinical data have illustrated the validity of other preservation systems in preserving cardiac allografts, and many of these devices have shown promise in potentially prolonging the tolerated ischemic time beyond the accepted standard.

View Article and Find Full Text PDF

Cardioplegic Machine Perfusion of Hearts Donated after Circulatory Death.

J Cardiovasc Transl Res

September 2025

Department of Cardiac Surgery, University Hospital Halle (Saale), University of Halle, Ernst-Grube-Straße 40, 06120, Halle (Saale), Germany.

We compared the effects of ex-vivo machine perfusion (EVMP) of hearts donated after circulatory death (DCD) with the single-shot solutions HTK-N and Del Nido cardioplegia (DNC) on left-ventricular (LV) contractility and myocardial microcirculation. In a DCD pig model, hearts were maintained by EVMP with hypothermic, oxygenated HTK-N (DCD-HTK-N; N = 8) or DNC (DCD-DNC; N = 8) followed by reperfusion with blood, including assessment of contractility and microcirculation with Laser-Doppler-Flow (LDF). We performed transcriptomics using microarrays.

View Article and Find Full Text PDF